نتایج جستجو برای: dosimetry

تعداد نتایج: 8115  

Journal: :Physics in medicine and biology 2006
M E Miquel K S Rhode P L Acher N D Macdougall J Blackall R P Gaston S Hegde S L Morris R Beaney C Deehan R Popert S F Keevil

Post-implantation dosimetry is an important element of permanent prostate brachytherapy. This process relies on accurate localization of implanted seeds relative to the surrounding organs. Localization is commonly achieved using CT images, which provide suboptimal prostate delineation. On MR images, conversely, prostate visualization is excellent but seed localization is imprecise due to distor...

Journal: :Radiation protection dosimetry 2005
K Faulkner P Ortiz-Lopez E Vano

Patient dosimetry is performed in radiology and interventional radiology to assess whether deterministic injuries may occur and to establish the risk of stochastic effects. A fundamental problem for patient dosimetry is that no single quantity can be used to accurately assess both the risk of stochastic effects and whether deterministic injuries will occur following a specific examination or pr...

2014
Mauro Valente Wladimir Molina José Vedelago

Radiation dosimetry by Fricke gel was largely used, generally focused and optimized for radiotherapy applications therefore involving relative high dose levels. Fricke gel dosimetry has several advantages, like dose rate and LET almost independence, 3D mapping, among other. This work presents a novel Fricke gel dosimeter optimized for low dose levels. Several chemical composition were studied v...

Journal: :Physics in medicine and biology 2011
I Mrčela T Bokulić J Izewska M Budanec A Fröbe Z Kusić

A commercial optically stimulated luminescence (OSL) dosimetry system was investigated for in vivo dosimetry in radiation therapy. Dosimetric characteristics of InLight dot dosimeters and a microStar reader (Landauer Inc.) were tested in (60)Co beams. The reading uncertainty of a single dosimeter was 0.6%. The reproducibility of a set of dosimeters after a single irradiation was 1.6%, while in ...

2008
M. F. Desrosiers J. M. Puhl S. L. Cooper

NIST developed the alanine dosimetry system in the early 1990s to replace radiochromic dye film dosimeters. Later in the decade the alanine system was firmly established as a transfer service for high-dose radiation dosimetry and an integral part of the internal calibration scheme supporting these services. Over the course of the last decade, routine monitoring of the system revealed a small bu...

Journal: :Journal of radiation research 2006
Kenichi Tanaka Satoru Endo Alexander Ivannikov Shin Toyoda Eldana Tieliewuhan Kassym Zhumadilov Chuzo Miyazawa Shinji Suga Kazuhide Kitagawa Masaharu Hoshi

The influence of X-ray baggage scanning on electron spin resonance (ESR) dosimetry studies around the Semipalatinsk Nuclear Test Site (SNTS) has been examined at Incheon Airport in Korea, which is a transfer point of the routes from Kazakhstan to Japan. Utilized dosimeters are Japanese human tooth enamel for ESR and glass dosimeters. The difference between the estimated doses with the X-ray sca...

2017
Russ Kuker Manuel Sztejnberg Seza Gulec

Although radioactive iodine imaging and therapy are one of the earliest applications of theranostics, there still remain a number of unresolved clinical questions as to the optimization of diagnostic techniques and dosimetry protocols. I-124 as a positron emission tomography (PET) radiotracer has the potential to improve the current clinical practice in the diagnosis and treatment of differenti...

2013
T Gorjiara Z Kuncic J Adamovics C Baldock

PRESAGE is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE formulations irradiated by a 62 MeV proton beam were compared with that in water using GEANT4 Monte Carlo simulations. The dose delivered by secondary particles was also calculated. Our results s...

2005
Lesley A. Buckley

Radiation dosimetry is used to quantify the dose delivered during radiation therapy by using ionization chambers with several correction factors. Knowledge of these factors is needed at well below the 1% level in order to maintain the overall uncertainty on the reference dosimetry near 1-2%. The small magnitude of the corrections renders measurements very difficult. Monte Carlo calculations are...

Journal: :Physics in medicine and biology 2009
G Massillon-Jl R Minniti M G Mitch M J Maryanski C G Soares

Absorbed dose distributions in 3D imparted by a single (90)Sr/(90)Y beta particle seed source of the type used for intravascular brachytherapy were investigated. A polymer gel dosimetry medium was used as a dosemeter and phantom, while a special high-resolution laser CT scanner with a spatial resolution of 100 microm in all dimensions was used to quantify the data. We have measured the radial d...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید