نتایج جستجو برای: dose equivalent response
تعداد نتایج: 1345511 فیلتر نتایج به سال:
PURPOSE Our group previously introduced an in vivo proton range verification methodology in which a silicon diode array system is used to correlate the dose rate profile per range modulation wheel cycle of the detector signal to the water-equivalent path length (WEPL) for passively scattered proton beam delivery. The implementation of this system requires a set of calibration data to establish ...
background: since 1996 the assessment of environmental gamma radiation dose in residential areas of iranian towns and cities has been accomplished for 10 counties. as a practical method and based on the results of a pilot study, in order to attribute the final results to the whole residential area of a town five stations were selected for every town. the location of individual station was studi...
Introduction: The purpose of this study is to build homogeneous equivalent phantom chest in order to provide the necessary ability for checking the image quality in radiographic tests in four age groups of children in terms of the most recent age group categorization ICRP103. This phantom provides the features of weakness and discrepancies similar to body and can be consi...
background: exposure conditions in ct examinations are quite different from conventional xray. in ct examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. in order to calculate organ effective dose in chest ct, monte carlo simulation has been used in this study. materials and methods: the impact survey data were used to determine the parameter...
In current design practice, the dynamic wind loads are described in terms of the equivalent static wind loads based on the gust response factor. This approach results in a distribution of the equivalent static loading similar to the mean static wind load distribution, which may not always be a physically meaningful and realistic load description. In this paper, the equivalent static load repres...
objecive prolonged and uncontrolled refractory status epilepticus (se) is a life-threatening medical emergency in children (1,2,3). there is no consensus on the optimal therapy for refractory status epilepticus (1). the aim of this study was to develop a new method for treating patients with refractory status epilepticus. materials & methods ten children with refractory status epilepticus in mo...
background: in this work investigation of the normoxic pagat polymer gel dosimeter such as sensitivity, the r2-dose response with post time and the percentage depth dose (pdd) of pagat polymer gel dosimeter have been undertaken. materials and methods: using mri, the formulation to give the maximum change in the transverse relaxation rate r2 was determined to be 4.5% n,n'-methylenbis- acryl...
Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8±0.35 at 25.5keV (50kVp) peaking at 12.1±0.5 at 54keV (125kVp) to 0.975±0.03 at 2300keV (10MV) when norm...
UNLABELLED The study aimed at identifying patient-specific dosimetric and nondosimetric factors predicting outcome of non-Hodgkin lymphoma patients after (131)I-tositumomab radioimmunotherapy for potential use in treatment planning. METHODS Tumor-absorbed dose measures were estimated for 130 tumors in 39 relapsed or refractory non-Hodgkin lymphoma patients by coupling SPECT/CT imaging with th...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید