A. Jabbary Arfaee, A.S. Meigooni, E. Rajab Bolookat, H.A. Nedaie, H.R. Mirzaei, R. Jaberi, S. Gholami, S. Rabi Mahdavi,

Background: One major challenge in brachytherapy is to verify the accuracy of dose distributions calculated by the treatment planning system. In this project, a new phantom design has been introduced for quality assurance of dose distributions in gynocological (GYN) brachytherapy implants using EBT GafChromic film. Materials and Methods: This phantom has been designed and fabricated from 90 sla...

2003
Patrick N. McDermott Tongming He A. DeYoung

The dose calculation accuracy of a commercial pencil beam IMRT planning system is evaluated by comparison with Monte Carlo calculations and measurements in an anthropomorphic phantom. The target volume is in the right lung and mediastinum and thus significant tissue inhomogeneities are present. The Monte Carlo code is an adaptation of the MCNP code and the measurements were made with TLD and fi...

2012
Mark K.H. Chan Dora L.W. Kwong Sherry C.Y. Ng Anthony S.M. Tong Eric K.W. Tam

The dynamic movement of radiation beam in real-time tumor tracking may cause overdosing to critical organs surrounding the target. The primary objective of this study was to verify the accuracy of the 4D planning module incorporated in CyberKnife treatment planning system. The secondary objective was to evaluate the error that may occur in the case of a systematic change of motion pattern. Meas...

Journal: :RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren 2015

2014
Yanqun Zhao Guohai Qi Gang Yin Xianliang Wang Pei Wang Jian Li Mingyong Xiao Jie Li Shengwei Kang Xiongfei Liao

BACKGROUND The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle ...

2017
David Paulu Parham Alaei

There are an increasing number of radiation therapy patients with hip prosthesis. The common method of minimizing treatment planning inaccuracies is to avoid radiation beams to transit through the prosthesis. However, the beams often exit through them, especially when the patient has a double-prosthesis. Modern treatment planning systems employ algorithms with improved dose calculation accuraci...

Journal: :Polish Journal of Medical Physics and Engineering 2021

Abstract Purpose: Advanced radiation therapy techniques use small fields in treatment planning and delivery. Small have the advantage of more accurate dose delivery, but with cost some complications dosimetry. Different calculation algorithms imported various systems (TPSs) which each them has different accuracy. Monte Carlo (MC) simulation been reported as one methods for calculating distribut...

2017
Keisuke Usui Koichi Ogawa Keisuke Sasai

Cone-beam computed tomography (CBCT) images have inaccurate CT numbers because of scattered photons. Thus, quantitative analysis of scattered photons that affect an electron density (ED) curve and calculated doses may be effective information to achieve CBCT-based radiation treatment planning. We quantitatively evaluated the effect of scattered photons on the accuracy of dose calculations from ...

2008
Ye Angela Hu Haijun Song Zhe Chen Sumin Zhou Fang‐Fang Yin

The electron Monte Carlo (eMC) dose calculation algorithm of the Eclipse treatment planning system is based heavily upon Monte Carlo simulation of the linac head and modeling of the linac beam characteristics with minimal measurement of beam data. Commissioning of the eMC algorithm on multiple identical linacs provided a unique opportunity to systematically evaluate the algorithm with actual me...