نتایج جستجو برای: density calibration

تعداد نتایج: 463947  

2015
Haining Zhang Huanbo Gao

This paper uses an analysis of Speeded up Robust Feature (SURF), based on the method of Linear Interpolation for camera distortion calibration, for high-density crowd counting. The eigenvalues are built on the Gray Level Co-occurrence Matrix (GLCM) features and the SURF features. Through the method of linear interpolation, weight values are interpolated to reduce the error, which is caused by c...

Journal: :AGIT Journal 2016
Dzenan Dzafic Daniel Klein-Ridder Pierre Schoonbrood Dominik Franke Stefan Kowalewski

Surfaces influence comfort as well as energy consumption or necessary strength during wheelchair driving. However, information about surfaces is only scarcely available in OpenStreetMap. To increase the density of this information, smartphone sensors combined with crowdsourcing is used. In this work, a concept is introduced, which analyses the surface using vertical acceleration. The focus is p...

2008
M Zehetmayer H W Weber

We present a new method of rapidly determining the local critical current density (Jc) in large superconducting pellets without destroying the sample. We show that magnetoscan data averaged over a certain small sample area can be mapped directly onto absolute values of Jc. This conclusion and the corresponding calibration curve are based on results from magnetoscan and from SQUID measurements o...

2003
Steven L. Wright Steven E. Millman Chai Wah Wu Paul F. Greier S. L. Wright S. Millman C. W. Wu P. F. Greier K. Yamauchi K. Numano K. Sumiyoshi

A new method of color management is described which takes advantage of the high pixel density achievable with TFTLCDs. In this method, a calibration 10-bit look-up-table can be loaded into the monitor and implemented as a 2x2 spatial dither block to provide a 10-bit color palette for 8-bit color drive. Other subpixel dithering techniques are also described for monochrome and color high-resoluti...

2007
I. Martı́ - Vidal J. M. Marcaide

Phase self-calibration (or selfcal) is an algorithm often used in the calibration of interferometric observations in astronomy. Although a powerful tool, this algorithm presents strong limitations when applied to data with a low signal-to-noise ratio. We analyze the artifacts that the phase selfcal algorithm produces when applied to extremely noisy data. We show how the phase selfcal may genera...

2012
Flavio Fabbri Marco Zuniga Daniele Puccinelli Pedro José Marrón

Empirical studies on link blacklisting show that the delivery rate is very sensitive to the calibration of the blacklisting threshold. If the calibration is too restrictive (the threshold is too high), all neighbors get blacklisted. On the other hand, if the calibration is too loose (the threshold is too low), unreliable links get selected. This paper investigates blacklisting analytically usin...

2007
Roman M. Balabin Ravilya Z. Safieva Ekaterina I. Lomakina

Six popular approaches of «NIR spectrum–property» calibration model building are compared in this work on the basis of a gasoline spectral data. These approaches are: multiple linear regression (MLR), principal component regression (PCR), linear partial least squares regression (PLS), polynomial partial least squares regression (Poly-PLS), spline partial least squares regression (Spline-PLS) an...

2008
Daniel Goldin

1. JET RECONSTRUCTION AT ATLAS The ATLAS calorimeter is non-compensating. Its calibration may be performed either globally or locally. Global calibration is a top-down technique where hadronic objects from specific physics processes are reconstructed relative to a fixed (global) electromagnetic scale. The weights are subsequently applied to calorimeter layers and individual cells based on the d...

Journal: :Journal of lipid research 1994
M Ala-Korpela A Korhonen J Keisala S Hörkkö P Korpi L P Ingman J Jokisaari M J Savolainen Y A Kesäniemi

A new method is presented for absolute quantitation of lipid and protein contents of human lipoproteins directly from plasma. The method enables complete lipoprotein lipid profiles to be obtained in a total time of less than one hour. Absolute concentrations of triglycerides, phospholipids, total cholesterol, free cholesterol, esterified cholesterol, total proteins, and total masses can be esti...

Journal: :Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research 1997
S L Hui S Gao X H Zhou C C Johnston Y Lu C C Glüer S Grampp H Genant

The International Dual-Photon X-Ray Absorptiometry (DXA) Standardization Committee (IDSC) conducted a cross-calibration study among three models of DXA machines from three different manufacturers. In that study, 100 subjects were scanned on all three machines. A set of equations were derived to convert bone mineral density (BMD) on each machine to a "standardized BMD" (sBMD) such that sBMD from...

نمودار تعداد نتایج جستجو در هر سال