نتایج جستجو برای: conductivity detector

تعداد نتایج: 108981  

2010

The physical properties of the gas, the composition of the gas during upset, and the operation of the gas in hazardous locations can affect the analytical method development and the hardware design. The gas chromatograph must be compatible with the physical properties (e.g., the physical state) of the sample. The sample must be introduced to the gas chromatograph as a single phase. Since on-lin...

Journal: :journal of medical signals and sensors 0
mohsen hajizadeh-safar m ghorbani s khoshkharam z ashrafi

gamma camera is an important apparatus in nuclear medicine imaging. its detection part is consists of a scintillation detector with aheavy collimator. substitution of semiconductor detectors instead of scintillator in these cameras has been effectively studied. in this study, it is aimed to introduce a new design of p-n semiconductor detector array for nuclear medicine imaging. a p-n semiconduc...

2015
Shanyu Wang Jiong Yang Trevor Toll Jihui Yang Wenqing Zhang Xinfeng Tang

Intriguing experimental results raised the question about the fundamental mechanisms governing the electron-hole coupling induced bipolar thermal conduction in semiconductors. Our combined theoretical analysis and experimental measurements show that in semiconductors bipolar thermal transport is in general a "conductivity-limiting" phenomenon, and it is thus controlled by the carrier mobility r...

ژورنال: سنجش و ایمنی پرتو 2018

This paper presents the study on the effect of detector type in estimating gamma rays buildup factor. In this regard, the flux buildup factors of gamma rays emitted by an isotropic point 60Co source in mean energy 1.253 MeV was evaluated after passing through the Pb, W, Zn, and Ti sample in thickness of 1-5 cm by MCNPX. Four common detector types in simulation of measurement was defined to esti...

ژورنال: سنجش و ایمنی پرتو 2020

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

حسین آفریده, , رحیم کوهی فایق, , غلامرضا اصلانی, , غلامرضا اطاعتی, , فریدون عباسی دوانی, ,

  In this project the neutron spectra from the reaction of deutron on beryllium muclei is measured. The energies of deuterons were 7, 10, 13 and 15 MeV, and these measurements are performed at 10, 30 and 50 degrees relative to the beam of deutrons. The detector used is 76 by 76 mm right circular cylender of NE-213 liquid scintillator. The zero crossing technique is used for gamma discriminatin....

J. Novotny Jr., T. Veselsky, V. Pastykova,

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید