نتایج جستجو برای: chip electrophoresis

تعداد نتایج: 101647  

Journal: :The Analyst 2002
Joseph Wang Martin Pumera Greg Collins Frantisek Opekar Ivan Jelínek

A miniaturized analytical system for separating and detecting inorganic explosive residues, based on the coupling of a micromachined capillary electrophoresis (CE) chip with a contactless conductivity detector is described. The low electroosmotic flow (EOF) of the poly(methylmethacrylate) (PMMA) chip material facilitates the rapid switching between analyses of cations and anions using the same ...

2011
Sandeep Kumar Jha You-Cheol Jang Rohit Chand Kamrul Islam Yong-Sang Kim

An integrated continuous-flow microfluidic chip was fabricated on glass substrate with PDMS based microchannels, cell lysis and PCR modules. Gold-microelectrodes were used to produce electrochemical cell lysis, while, indium-tin-oxide (ITO) microheater was used for thermal cycling of PCR reaction. The fabricated device was used for 20 cycles of PCR amplification of pancreatic cancer DNA marker ...

Journal: :Electrophoresis 2008
Chenlu Hou Amy E Herr

Clinical and point-of-care disease diagnostics promise to play an important role in personalized medicine, new approaches to global health, and health monitoring. Emerging instrument platforms based on lab-on-a-chip technology can confer performance advantages successfully exploited in electrophoresis and electrochromatography to affinity-based electrokinetic separations. This review surveys la...

Journal: :Electrophoresis 2003
Byoungsok Jung Rajiv Bharadwaj Juan G Santiago

Field-amplified sample stacking (FASS) leverages conductivity gradients between a volume of injected sample and the background buffer to increase sample concentration. A major challenge in applying FASS to on-chip assays is the initial setup of high-conductivity gradient boundaries in the region of the injected sample volume. We have designed, fabricated, and characterized a novel FASS-capillar...

Journal: :Analytical chemistry 2001
J Wang M P Chatrathi A Mulchandani W Chen

A miniaturized analytical system for separating and detecting toxic organophosphate nerve agent compounds, based on the coupling of a micromachined capillary electrophoresis chip with a thick-film amperometric detector, is described. Factors influencing the on-chip separation and detection processes have been optimized. Using a MES buffer (20 mM, pH 5.0) running buffer, a 72-mm-long separation ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2011
Xiaofang Gao Yo Tanaka Yasuhiko Sugii Kazuma Mawatari Takehiko Kitamori

Various separation processes have been integrated in microfluidics, such as capillary electrophoresis and chromatography, on a microchip. However, it is extremely difficult to separate a complicated biological system by conventional methods. Here, we report on a feasible structure and the culture condition of human renal proximal tubule epithelial cells (RPTECs), with the aim to construct a bio...

Journal: :Lab on a chip 2014
Huai-Song Wang Fang-Nan Xiao Zhong-Qiu Li Jun Ouyang Zeng-Qiang Wu Xing-Hua Xia Guo-Jun Zhou

A sensitive approach to the determination of reactive oxygen species (ROS) in puffs of cigarette smoke (CS) has been developed. The experimental system consists of a microfluidic chip electrophoresis and a laser induced fluorescence (LIF) device enhanced by localized surface plasmon resonance. Core-shell Ag@SiO2 nanoparticles were prepared and then immobilized on the surface of the microchannel...

2006
Orlin D. Velev Ketan H. Bhatt

We overview the ways in which electric fields can be used for on-chip manipulation and assembly of colloidal particles. Particles suspended in water readily respond to alternating (AC) or direct current (DC) electric fields. Charged particles in DC fields are moved towards oppositely charged electrodes by electrophoresis. Dielectrophoresis, particle mobility in AC fields, allows precise manipul...

Journal: :Analytical chemistry 2003
Frederic Laugere Rosanne M Guijt Jeroen Bastemeijer Gert van der Steen Axel Berthold Erik Baltussen Pascalina Sarro Gijs W K van Dedem Michiel Vellekoop Andre Bosschet

In this contribution, a capillary electrophoresis microdevice with an integrated on-chip contactless four-electrode conductivity detector is presented. A 6-cm-long, 70-microm-wide, and 20-microm-deep channel was etched in a glass substrate that was bonded to a second glass substrate in order to form a sealed channel. Four contactless electrodes (metal electrodes covered by 30-nm silicon carbide...

Journal: :Journal of chromatography. A 2004
Jongyoon Han Anup K Singh

We have developed novel protein gel electrophoresis techniques, sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and isoelectric focusing (IEF) in short microchannels (approximately millimeters) that take less than a minute. A photopatterning technique was used to cast in situ crosslinked polyacrylamide gel in a microchannel to perform SDS-PAGE. A fluorescent protein marker ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید