نتایج جستجو برای: beam ct
تعداد نتایج: 242842 فیلتر نتایج به سال:
X-ray computed tomography (CT) enables the visualisation and dimensional evaluation of both the internal and external geometry of a workpiece, it is therefore well suited for measuring geometric features that are otherwise inaccessible to tactile and optical instruments. Beam hardening is a wellknown physical process that can degrade the quality of CT images and influence edge detection algorit...
The goal is to perform geometric studies on cone-beam CT scanning along a three-dimensional (3D) spiral of variable radius. First, the background for variable radius spiral cone-beam scanning is given in the context of electron-beam CT/micro-CT. Then, necessary and sufficient conditions are proved for existence and uniqueness of PI lines inside the variable radius 3D spiral. These results are n...
In computed tomography (CT), the beam hardening effect has been known to be one of the major sources of deterministic error that leads to inaccuracy and artifact in the reconstructed images. Because of the polychromatic nature of the x-ray source used in CT and the energy-dependent attenuation of most materials, Beer's law no longer holds. As a result, errors are present in the acquired line in...
BACKGROUND The technologic improvements in Multislice scanners include the increment in the X-ray beam width. Some new CT scanners are equipped with a 320 detector row which allows a longitudinal coverage of 160 mm and a total of 640 slices for a single rotation. When such parameters are used the length of the traditional pencil chamber (10 cm) is no more appropriate to measure the standard wei...
BACKGROUND To investigate the effect of computed tomography (CT) contrast enhancement (CE) on the 3D dose distributions of non-coplanar small field beams in the CyberKnife (CK) treatment planning system (TPS) for the stereotactic ablative radiotherapy (SABR). METHODS Twenty-two pre-CE CT treatment plans were recruited to this retrospective plan study. Their post-CE CT plans were based on the ...
X-ray computed tomography (CT) images obtained with a polychromatic X-ray source were simulated by computer for homogeneous solutions and suspensions containing a heavy element. When the K-edge of the element was near the peak energy of the polychromatic X-ray spectrum, the degree of beam hardening in the simulated CT image strongly depended on the atomic number and molar concentration of the ...
Computed Tomography (CT) images often suffer from artifacts caused by misaligned scanner geometry of CT system. Calibration and correction must be done before image reconstruction. A method for calibration of misaligned scanner geometry in cone-beam CT with single-circle orbit is proposed. In this method, a four-point phantom is used to estimate a set of parameters that describe the geometry of...
CONCLUSION The saccular duct and endolymphatic sinus run in the bony groove, before reaching the orifice of the vestibular aqueduct. We first clinically visualized this sulciform groove using three-dimensional (3D) cone beam CT images. This strategy can be useful to assess the condition of the saccular duct and endolymphatic sinus concerning the longitudinal flow system of endolymph. OBJECTIV...
Quantitative tissue classification using dual-energy CT has the potential to improve accuracy in radiation therapy dose planning as it provides more information about material composition of scanned objects than the currently used methods based on single-energy CT. One problem that hinders successful application of both singleand dualenergy CT is the presence of beam hardening and scatter artif...
Conventionally, surgery and procedural-based radiology are performed on different premises. With advances in imaging technology, the operating room is rapidly being transformed into an intraoperative imaging suite. Diagnostic imaging in conjunction with surgery has great utility and by all accounts has great future potential. During the last decade, cone beam computed tomography (CT) scanners h...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید