نتایج جستجو برای: active power filter
تعداد نتایج: 1011413 فیلتر نتایج به سال:
In 2006 the set up of one test bench for superconducting magnets of FAIR was finished at GSI. A second one is under construction. After commissioning of both test stands magnetic measurements of up to 8 superconducting magnets per month will be possible. The dedicated power converter must supply DC currents and ramped currents up to 11000A and provide output voltages up to +/-100V. This gives a...
This paper presents a grid connected photovoltaic system, which acts as both power generator and active power filter (APF), based on Flying Capacitor Multicell (FCM) converter. Increase in the number of output voltage levels, natural self-balancing of flying capacitors and dc link voltage and lower power rating of components are the main futures of FCM converter compared with conventional multi...
This paper presents a grid connected photovoltaic system, which acts as both power generator and active power filter (APF), based on Flying Capacitor Multicell (FCM) converter. Increase in the number of output voltage levels, natural self-balancing of flying capacitors and dc link voltage and lower power rating of components are the main futures of FCM converter compared with conventional multi...
Active power conditioners have been developed over the years to solve the problems to improve power quality. Among which shunt active power conditioners is used to eliminate load current harmonics and reactive power compensation. The controller ensures that the dc-side capacitor voltage is nearly constant with small ripple besides extracting fundamental reference currents. The PLL block assists...
Due to the advancement in power electronic equipments and increase in the usage of non-linear loads in power distribution system, the undesirable harmonics are introduced that degrade the quality of power. Presence of harmonics are always detrimental to power system that results in irreversible failure of electrical components, sometimes apart from frequently known heating issues in it. There a...
The design process for a fuel-cell-based inverter system for domestic use is discussed. The peculiar characteristics of the fuel cell stack energy source require the use of a battery for buffering. The fuel cell characteristics and the battery requirements for this application are discussed. A large number of different possible solutions are examined. The proposed solution uses an active filter...
Power quality standards (IEEE-519) require to limit the total harmonic distortion within satisfactory range caused by power electronic based devices. Our work deals with the design of hybrid active filter to reduce current perturbations produced by power electronics based devices. The Instantaneous Active and Reactive Power Method (pq) is used to perform the identification of disturbing current...
The paper presents a three-dimensional space-vector-modulation scheme for three-phase four-wire active power filters. The focus is on the implementation of a fixed frequency pulse width modulation (PWM) scheme with a minimum number of switch commutations per period and maximum DC bus voltage utilisation. For three-wire applications, space vector modulation is known to provide better utilisation...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید