نتایج جستجو برای: 3d gel dosimetry
تعداد نتایج: 299187 فیلتر نتایج به سال:
INTRODUCTION The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. OBJECTIVE A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of meas...
A preliminary investigation into the efficacy of a new 3D dosimetry material, RadGel™, for verification of radiation therapy dose distributions is presented. Small volumes of RadGel™ were found to exhibit a linear, reproducible response to dose. A gradual increase in optical-density (OD) with time was observed, suggesting scanning should be completed within 18 hours to keep a linear correlation...
PRESAGE is a radiochromic solid dosimeter which shows promising potential for 3D proton beam dosimetry. Since an idea dosimeter should be water-equivalent, total depth dose distributions in two PRESAGE formulations irradiated by a 62 MeV proton beam were compared with that in water using GEANT4 Monte Carlo simulations. The dose delivered by secondary particles was also calculated. Our results s...
Introduction: In radiotherapy, treatment planning methods are evaluating and transforming every day, so precision in calculation and determination of dose delivery process is performing more important role in radiotherapy than past. In modern radiotherapy treatments, deramatically increase of small fields utilization, causes the polymeric gels has known as the most reliable dos...
Introduction: Magnetic resonance imaging dependent polymer gel dosimetry is a technique that offers unique advantages for implementing increasingly complex radiotherapy procedures, due to the high spatial resolution and volumetric dosimetry capabilities. The technique involves the estimation of radiation dose distribution based on the changes in MR relaxation parameters caused by radiation indu...
Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. Accurate beam profile measurements of such beams are crucial for a precise and effective treatment. In this work four different dosimetric methods have been used for profile measurements of three small 6 MV circular fields having diameters of 7.5, 15.0 and 30.0 mm. A small sensitive v...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید