نتایج جستجو برای: 3 300 mm
تعداد نتایج: 1995155 فیلتر نتایج به سال:
B. Wang, Z. G. Yang, X. F. Zhang, Y. T. Wang, C. P. Nie, Q. Liu, State Key Laboratory of Advanced Metallurgy, University of Science and Technology Beijing, Beijing, China Z. G. Yang, Special Steel Plant, Laiwu Iron & Steel Co. Ltd., Laiwu, China B. Wang, H. B. Dong, Department of Engineering, University of Leicester, Leicester, UK In the current study, a 260 mm × 300 mm bloom mould was investig...
In this paper, we present an airborne 3-D volumetric imaging system based on capacitive micromachined ultrasonic transducers (CMUTs). For this purpose we fabricated 89-kHz CMUTs where each CMUT is made of a circular single-crystal silicon plate with a radius of 1mm and a thickness of 20 μm, which is actuated by electrostatic force through a 20-μm vacuum gap. The measured transmit sensitivity at...
Objective Compare nasal endoscopy with 3 mm versus conventional 4 mm rigid 30° endoscopes for visualization, patient comfort, and examiner ease. Methods Ten adults with no previous sinus surgery underwent bilateral nasal endoscopy with both 4 mm and 3 mm endoscopes (resulting in 20 paired nasal endoscopies). Visualization, patient discomfort and examiner's difficulty were assessed with every ...
Combined QM/MM calculations of an activesite of Cytochrome P450cam have been performed, before and after a binding process of Cytochrome P450cam to Putidaredoxin. The calculations have been carried out for two coordination spheres of the heme active-site of Cytochrome P450cam, namely a 5-coordinated, and a 6coordinated system of this protein having a water molecule as a 6th ligand. An experimen...
A new airborne particle spectrometer has been developed with the same measurement capabilities of the Forward Scattering Spectrometer Probes (FSSP) models 100 and 300 (FSSP-300 and FSSP100), two-dimensional optical imaging probe (2D-OAP), the Multiangle Aerosol Spectrometer Probe (MASP) and hot-wire liquid water probe, but with a single integrated system. The cloud, aerosol and precipitation sp...
This study aimed to investigate the preferential collagen fibril alignment in unloaded and loaded tendons using elastic scattering spectroscopy. The device consisted of an optical probe, a pulsed light source (320-860 nm), a spectrometer and a PC. Two probes with either 2.75 mm or 300 microm source-detector separations were used to monitor deep and superficial layers, respectively. Equine super...
X-ray powder diffraction is one of the most potential characterization tools and a nondestructive technique for characterizing both organic and inorganic crystalline materials. The method previously used for measuring phase identification, quantitative analysis and to determine structure imperfections of samples from various disciplines such as geology, polymeric, environmental, pharmaceutical,...
A novel large self-expanding endovascular stent was designed with strut thickness of 70 μm × 70 μm width. The method was developed and investigated to identify a novel simpler technique in aortic aneurysm therapy. Stage 1 analysis was performed after deploying it in a virtual aneurysm model of 6 cm wide × 6 cm long fusiform hyper-elastic anisotropic design. At cell width of 9 mm, there was no b...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید