نتایج جستجو برای: 1 three different preprocessing methods namely multiplicative scatter correction msc
تعداد نتایج: 6026014 فیلتر نتایج به سال:
MSC (mesenchymal stromal cells) can differentiate into renal adult cells, and have anti-inflammatory and immune-modulating activity. In the present study, we investigated whether MSC have protective/reparative effects in anti-Thy1 disease, an Ab (antibody)-induced mesangiolysis resulting in mesangioproliferative nephritis. We studied five groups of rats: (i) rats injected with anti-Thy1.1 Ab on...
UNLABELLED This study investigates the ability of artificial neural networks (ANN) to simultaneously correct for attenuation and Compton scattering in scintigraphic imaging. METHODS Three sets of experiments are conducted using images of radioactive sources with various shapes and distributions in a homogeneous medium. Numerical Monte Carlo simulations and physical phantom acquisitions of rad...
PURPOSE Scatter is a very important artifact causing factor in dental cone-beam CT (CBCT), which has a major influence on the detectability of details within images. This work aimed to improve the image quality of dental CBCT through scatter correction. METHODS Scatter was estimated in the projection domain from the low frequency component of the difference between the raw CBCT projection and...
BACKGROUND Physiological noise is one of the major confounds for fMRI. A common class of correction methods model noise from peripheral measures, such as ECGs or pneumatic belts. However, physiological noise correction has not emerged as a standard preprocessing step for fMRI data yet due to: (1) the varying data quality of physiological recordings, (2) non-standardized peripheral data formats ...
2 Cover illustration: The logarithm of a 123 I point spread function. The point source was simulated at 14.0 cm distance from the collimator in air, with the SIMIND version described in Paper V, using parameters corresponding to a GE Millennium MPR with 2.3 × 2.3 m 2 field of view. The grey scale is processed. To Björn, family and friends If you don't care where you are, you ain't lost. ABSTRAC...
Automatic cell recognition in bright field microscopy is an inherently difficult task due to the immense variability of cell appearance. Yet, it is essential for a highthroughput robotic system. In this paper, we employed a pixel patch decomposition method to detect cultured cells in bright field images. To increase the classification accuracy, we proposed a novel Fisher's Linear Discriminant (...
OBJECTIVE The radioactivity count distribution in the brain must be determined accurately to accurately measure cerebral blood flow (CBF). Scatter and attenuation are factors that compromise the accuracy of determining radioactivity counts in the brain. METHODS We compared regional CBF in patients by an autoradiographic method using N-isopropyl-p-[123I] iodoamphetamine when, first, attenuatio...
Kilovoltage cone-beam CT (kV CBCT) can be acquired during the delivery of volumetric modulated arc therapy (VMAT), in order to obtain an image of the patient during treatment. However, the quality of such CBCTs is degraded by megavoltage (MV) scatter from the treatment beam onto the imaging panel. The objective of this paper is to introduce a novel MV scatter correction method for simultaneous ...
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید