نتایج جستجو برای: wind load

تعداد نتایج: 227639  

2015
Guoyan Cao Karolos M Grigoriadis Yaw D Nyanteh

Wind turbine conversion systems require feedback control to achieve reliable wind turbine operation and stable current supply. A robust linear parameter varying (LPV) controller is proposed to reduce the structural loads and improve the power extraction of a horizontal axis wind turbine operating in both the partial load and the full load regions. The LPV model is derived from the wind turbine ...

2013
Shan Zuo Y. D. Song Lei Wang Qing-wang Song

Offshore floating wind turbine (OFWT) has gained increasing attention during the past decade because of the offshore high-quality wind power and complex load environment. The control system is a tradeoff between power tracking and fatigue load reduction in the above-rated wind speed area. In allusion to the external disturbances and uncertain system parameters of OFWT due to the proximity to lo...

2006

Renewable energy policies, such as the Renewable Portfolio Standard, arising from increasing environmental concerns have set very ambitious targets for wind power penetration in electric power systems throughout the world. In many cases, the geographical locations with good wind resources are not close to the main load centers. It becomes extremely important to assess adequate transmission faci...

Journal: :ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A: Civil Engineering 2017

2011
Mohsen Bashir Javad Sadeh

Using hybrid renewable energy is one of the best alternatives to supply the electrical energy at remote areas. Renewable energy sources are depended to weather conditions or other factors, so for supplying load with renewable sources appropriate capacity of these sources should be selected. In determining the capacity of renewable energy such as wind and solar, considering the stochastic nature...

2010
Pawan Sharma

This paper presents automatic reactive power control of the isolated wind-diesel hybrid power systems. The synchronous generator (SG) is used for power generation from diesel and the induction generator (IG) is used for electric power generation from wind turbine. To minimize the gap between reactive power generation and demand, the variable sources of reactive power is used such as static sync...

2001
Yin Zhou Ming Gu Haifan Xiang

Although on the same theoretical basis, the current standards of major countries have set out two evidently different distributions of along-wind static equivalent wind loads, one is the same as the mean wind force and the other is the same as the first mode shape, on tall buildings. In this paper, the fluctuating static equivalent wind load is evaluated as mean, background and resonant compone...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید