نتایج جستجو برای: ultimate load capacity
تعداد نتایج: 443030 فیلتر نتایج به سال:
In this paper, load-carrying capacity in steel shear wall (SSW) was estimated using artificial neural networks (ANNs). The SSW parameters including load-carrying capacity (as ANN’s target), plate thickness, thickness of stiffener, diagonal stiffener distance, horizontal stiffener distance and gravity load (as ANN’s inputs) are used in this paper to train the ANNs. 144 samples data of each of th...
In order to explore the influence of length and width CFRP as well anchor spacing on reinforcement effectiveness plates concrete beams (RC beams) under secondary load, 7 anchored damaged FRP reinforced are used test beams, 1 unanchored beam is a control beam, structural indicators such ultimate load bending strength analyzed in result. The conclusion that composite plate can effectively prevent...
This paper deals with the study of a highly durable polyester polymer concrete reinforced with glass fibre reinforced polymer rebars. The paper describes the properties of this specific concrete, which were tested using different experimental techniques such as porosimetry, scanning electron microscopy and petrography. Likewise, characterisation in a macro-scale was carried out to define the me...
This study examines the capability of the Relevance Vector Machine (RVM) and Multivariate Adaptive Regression Spline (MARS) for prediction of ultimate capacity of driven piles and drilled shafts. RVM is a sparse method for training generalized linear models, while MARS technique is basically an adaptive piece-wise regression approach. In this paper, pile capacity prediction models are developed...
Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP) laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as ...
The grouted mortise-tenon joint, invented as the connection between large prefabricated elements, is most important component in underground structures. This paper conducts analysis of load-carrying capacity performance and failure mode with 1 : prototype test key working direction different double joint types for metro station. resistance moment developed used to analyze bending bearing charac...
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection '~md the overall integrity of the structure. This paper presents the results of a four-year research program conducted to i...
At present, the radius of wind turbine rotors ranges from several meters to one hundred meters, or even more, which extends Reynolds number of the airfoil profile from the order of 105 to 107. Taking the blade for 3MW wind turbines as an example, the influence of Reynolds number on the aerodynamic design of a wind turbine blade is studied. To make the study more general, two kinds of multi-obje...
The purpose of this study is to investigate bending moment and the axial load capacity of a pressurized pipe suffering from a through-wall circumferential crack repaired by a composite sleeve. The three-dimensional finite element method (FEM) was adopted to compute the results, and the failure assessment diagram (FAD) was employed to investigate the failure behavior of the repaired pipe. The fi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید