نتایج جستجو برای: the measured equivalent dose d_e

تعداد نتایج: 16116163  

Introduction: Environmental and occupational human exposure from neutron source can lead to the serious biologic effects. The aim of this study is to evaluate the cancer incidence risk for various human organs at different neutron dose levels due to exposure from an Americium-241/Beryllium (Am-241/Be), a standard neutron source for calibration purposes. Material and Methods: We measured ambient...

Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...

A.R. Farajollahi, F. Pak, M. Horsfield, Z. Myabi,

Background: In this study the basic radiation properties of N-isopropylacrylamaide polymer gel dosimeter were determined together with verification of its soft tissue equivalency. Materials and Methods: The NIPAM gel was prepared and irradiated approximately 2 h after manufacturing. The magnetic resonance (MR) images were made 24 h after irradiation. The nuclear magnetic resonance (NMR) respons...

Journal: :iranian journal of radiation research 0
f. pake department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran a. takavar department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.a. nedaie department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.r. saligheh rad department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran e. eqlimi department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran v. vaezzadeh department of radiotherapy oncology, cancer research centre, cancer institute, tehran university of medical sciences, tehran, iran

background:  in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...

Journal: :iranian journal of radiation research 0
mojisola usikalu department of physics, covenant university, p.m.b 1023, ota, nigeria p.p. maleka environmental radioactivity laboratory, ithemba labs, somerset west, south africa m. malik material science department, ithemba labs, somerset west, south africa k.d. oyeyemi department of physics, covenant university, p.m.b 1023, ota, nigeria o.o. adewoyin department of physics, covenant university, p.m.b 1023, ota, nigeria

background: natural radionuclides are always present in the environment. human exposure to the background radiation is inevitable. it is therefore important to assess health risk associated with these radionuclides. materials and methods: the distribution of natural radionuclides 238u, 232th and 40k in soil samples collected from all the twenty (20) local governments headquarter areas in ogun s...

M. Ravikumar, R. Ravichandran, S. Sathiyan,

Background: To evaluate the risk involved, there is need to know the quantum of personnel exposures in whole service. Dose reports from an Oncology Centre over 7 block periods, 5 years each from 1979 till 2013 are analyzed. Materials and Methods: Personnel monitoring (PM) reports till 1990s with film badges and later thermoluminescent (TL) badges (CaSo4.Dy) were evaluated. 35 years total servic...

Journal: :Japanese Journal of Radiological Technology 1996

Journal: :iranian journal of medical physics 0
tayyeb allahverdi pourfallah biochemistry and biophysics dept., faculty of medicine, mazandaran university of medical sciences, sari, iran maryam shahidi biochemistry and biophysics dept., faculty of medicine, mazandaran university of medical sciences, sari, iran

introduction in this study, effective dose equivalent for the public due to internal exposure to 222radon (222rn) was evaluated in three regions of ramsar, a northern coastal city in iran.                                materials and methods measurements were carried out using a radon monitoring device. outdoor and indoor radon concentrations were measured within 24 hours with an integration in...

Background: The equivalent dose in the human body due to the natural gamma-emitting radionucides (238U, 232Th and 40K) in the surface soil surrounding the Consolidated Tin mine site in Bukuru-Jos, Nigeria has been determined in this study. Materials and Methods: Measurements of the soil natural radioactivity were made using a multi-channel pulseheight analyzer (Canberra Series 10 plus) coupled ...

AR Shirazi, M Oshaghi M Sadeghi, SR Mahdavi

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید