نتایج جستجو برای: tg 43
تعداد نتایج: 113774 فیلتر نتایج به سال:
background: fasting is an alternative method to induceanorexia. objectives: the biochemical factors of liver andserum and clinical signs were measured and documented in fivenon-lactating, non-pregnant cows following eight days of fasting.methods:five crossbred, non-lactating, and non-pregnantcattle were used in this study. they were fasted for 8 days_ totalfood deprivation; however, they had fr...
This study presents the results of EGSnrc Monte Carlo calculations of the dose distribution surrounding a high dose rate Yb brachytherapy source and 14 high dose rate and pulsed dose rate Ir brachytherapy sources. Energy-weighted spectra of emitted photons, a full set of TG-43 dosimetry parameters, along-away dose tables, and a description of the materials and geometry used for each source are ...
conclusions according to the results, the old dosimetry formalisms, overestimate the dose especially towards the applicator’s tip. while the tg-43u1 based software perform the calculations more accurately. results for a typical arrangement of 10 active pellets in the applicator, the percentage difference between doses obtained by the new algorithm at 1cm distance from the tip of the applicator ...
Model-based dose calculation algorithms have recently been incorporated into brachytherapy treatment planning systems, and their introduction requires critical evaluation before clinical implementation. Here, we present an experimental evaluation of Oncentra® Brachy Advanced Collapsed-cone Engine (ACE) for a multichannel vaginal cylinder (MCVC) applicator using radiochromic film. A uniform dose...
AIM To evolve a fast dose verification method for high-dose-rate (HDR) brachytherapy treatment plans and to demonstrate its applicability in different clinical cases. MATERIALS AND METHODS We developed a software tool in VC++ for the Varisource HDR unit for HDR dosimetry plan verification using TG-43 parameters. HDR treatment dosimetry of a number clinical cases using Varisource was verified ...
Since the publication of AAPM Task Group 60 report in 1999, a considerable amount of dosimetry data for the three coronary brachytherapy systems in use in the United States has been reported. A subgroup, Task Group 149, of the AAPM working group on Special Brachytherapy Modalities (Bruce Thomadsen, Chair) was charged to develop recommendations for dose calculation formalisms and the related con...
A robust model to directly represent output from contemporary brachytherapy calculation had been proposed and developed to make clinical implementation practicable. The model was used to minimize inherent uncertainties associated with the AAMP TG-43 formalism, with consolidation of the TG-43 parameters into new parameter to speed up computational time. Analytical computations were performed to ...
We questioned if acute administration of n-3 fatty acids (FA) carried in n-3 rich triglyceride (TG) emulsions provides neuroprotection in neonatal mice subjected to hypoxic-ischemic (H/I) brain injury. We examined specificity of FA, optimal doses, and therapeutic windows for neuroprotection after H/I. H/I insult was induced in C57BL/6J 10-day-old mice by right carotid artery ligation followed b...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید