نتایج جستجو برای: skin impedance

تعداد نتایج: 228262  

2010
Vedran Boras Slavko Vujević Dino Lovrić

The accurate and fast computation of the per unit length (pul) internal impedance of rectangular conductors is required in electromagnetic analysis of various engineering and scientific problems where high current frequencies are involved [1, 2]. This pul internal impedance of a rectangular conductor can also be used in more complicated conductor structures where the shape of the conductor is a...

2013
Joshua Kuang-Chao Chen Ann Yi-Chiun Chuang Georg Mathias Sprinzl Tao-Hsin Tung Lieber Po-Hung Li

Previous animal study revealed that post-implantation electrical detection levels significantly declined within days. The impact of cochlear implant (CI) insertion on human auditory pathway in terms of impedance and electrically evoked compound action potential (ECAP) variation within hours after surgery remains unclear, since at this time frequency mapping can only commence weeks after implant...

Journal: :IEEE Trans. Instrumentation and Measurement 2009
Tao Dai Andy Adler

Characterization of blood impedance properties is important to estimate clinical diagnostic indices such as haematocrit, glucose level and hydration. Current in vivo bioimpedance spectroscopy methods are performed on a body appendage and thus represent a combined measurement of all tissues in the measurement field, rather than the blood individually. This paper describes a novel in vivo measure...

Journal: :Open journal of nursing 2014
Linda L Chlan

Background: Critically ill patients receiving prolonged mechanical ventilatory support are at risk for loss of muscle mass and muscle strength from immobility. Feasible, non-invasive methods are needed to accurately obtain data on markers of muscle mass to design effective interventions and monitor patient progress during recovery from critical illness. Bioelectric impedance has been used in ot...

2010
DAEIL KWON MICHAEL H. AZARIAN MICHAEL PECHT Daeil Kwon Michael H. Azarian Michael Pecht

For electronic products, interconnect failures may occur due to mechanisms such as fatigue, creep, corrosion, and mechanical over-stress. Regardless of the failure mechanism, interconnect degradation often starts at a surface and propagates inward. DC resistance, which has been used by the electronics industry to monitor the reliability of board level interconnects, does not offer an adequate m...

Journal: :international journal of robotics 0
vahab khoshdel center of excellence on soft computing and intelligent information processing, mechanical engineering department, ferdowsi university of mashhad, iran ali akbarzadeh center of excellence on soft computing and intelligent information processing, mechanical engineering department, ferdowsi university of mashhad, iran hamid moeenfard center of excellence on soft computing and intelligent information processing, mechanical engineering department, ferdowsi university of mashhad, iran

in this study, a novel variable impedance control for a lower-limb rehabilitation robotic system using voltage control strategy is presented. the majority of existing control approaches are based on control torque strategy, which require the knowledge of robot dynamics as well as dynamic of patients. this requires the controller to overcome complex problems such as uncertainties and nonlinearit...

2003
Hasan YMERI B. NAUWELAERS Karen MAEX D. DE ROEST

The goal of this work was to model the influence of the substrate skin effects on the distributed mutual impedance per unit length parameters of multiple coupled onchip interconnects. The proposed analytic model is based on the frequency-dependent distribution of the current in the silicon substrate and the closed form integration approach. It is shown that the calculated frequency-dependent di...

2005
Helen Benjamin Shekhar Bhansali Steven B. Hoath William L. Pickens Rod Smallwood

The outermost layer of the human skin, the stratum corneum (SC), is comprised of structurally inter-positioned anatomical regions. This inter-positioning renders the electrical characterization of its individual region difficult. To address this difficulty, the SC’s electrical properties at the cellular level were investigated. Impedance measurements were performed using a planar microelectrode...

Journal: :BioMedical Engineering OnLine 2004
Emil S Valchinov Nicolas E Pallikarakis

BACKGROUND Laser bio-stimulation is a well-established procedure in Medical Acupuncture. Nevertheless there is still a confusion as to whether it works or the effect is just placebo. Although a plethora of scientific papers published, showing positive clinical results, there is still a lack of objective scientific proofs about the bio-stimulation effect of lasers used in Acupuncture. The object...

Journal: :Revista latino-americana de enfermagem 2011
Jose Maria Moran Jesus Maria Lavado-Garcia Juan Diego Pedrera-Zamorano

Among the methods available for assessing body composition, traditional methods like hydrodensitometry and skin-fold measurements are well known. In this review, we focus on the impedance and interactance methods, which use systems that are usually inexpensive, easily transportable and simple to operate. We also discuss the usefulness of dual energy X-ray absorptiometry, particularly for the me...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید