نتایج جستجو برای: rf values

تعداد نتایج: 536883  

1994
Dina Kravets C. Greg Plaxton

Given a sequence of n elements, the All Nearest Smaller Values (ANSV) problem is to nd, for each element in the sequence, the nearest element to the left (right) that is smaller, or to report that no such element exists. Time and work optimal algorithms for this problem are known on all the PRAM models 4, 6], but the running time of the best previous hypercube algorithm 9] is optimal only when ...

Journal: :The Journal of the Acoustical Society of America 2005
Douglas S Brungart Brian D Simpson Richard L Freyman

When a masking sound is spatially separated from a target speech signal, substantial releases from masking typically occur both for speech and noise maskers. However, when a delayed copy of the masker is also presented at the location of the target speech (a condition that has been referred to as the front target, right-front masker or F-RF configuration), the advantages of spatial separation v...

Journal: :Magnetic resonance in medicine 2018
Koray Ertan Soheil Taraghinia Alireza Sadeghi Ergin Atalar

PURPOSE Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. THEORY AND METHODS Two different field design methods are formulated to solve for the required curre...

2003
Magdalena L. Mendoza

The paper examined the value system in Philippine firms against the backdrop of Eastern-Western cultural dynamics in East Asia. The Asian milieu presents co-existence of cultural stasis and unease -balance and tension between Eastern values and Western ideas. Successful Asian countries demonstrated their ability to blend conflicting cultures and highlight certain values in order to promote nati...

2012
Igor Smirnov

This article is related to the experimental data regarding the ability of MRET Noise Field Generator (MRET NFG) placed at the distance of 7 feet from “phantom head” exposed to RF phones radiation to reduce specific absorption rate (SAR) of the water based solution inside “phantom head”. The core part of Generator is MRET polymer compound. Due to the fractal geometry structure of MRET polymer co...

Journal: :Rheumatology 2015
Anne Miller Alison L Nightingale Cormac J Sammon Kamal R Mahtani Tim A Holt Neil J McHugh Raashid A Luqmani

OBJECTIVE To investigate the diagnostic accuracy of RF as a test for RA in primary care and its impact on referral times using the Clinical Practice Research Datalink. METHODS We identified all patients with a first RF test recorded in the Clinical Practice Research Datalink between 1 January 2000 and 31 December 2008 and those diagnosed with RA within 2 years of testing. We calculated likeli...

Journal: :Journal of chromatographic science 2014
Apexa Patel Arpit Patwari Bhanubhai Suhagia

A sensitive, selective, precise and stability indicating a high-performance thin layer chromatographic method for the analysis of rufinamide (Rf) in bulk drug and its formulations was developed and validated. The method employed thin layer chromatography aluminum plates precoated with silica gel 60 F254 as the stationary phase. The solvent system consisted of chloroform : methanol : glacial ace...

Journal: :Artificial intelligence in medicine 2009
Dechao Wang Brendan Larder Andrew Revell Julio Montaner Richard Harrigan Frank De Wolf Joep Lange Scott Wegner Lidia Ruiz María Jésus Pérez-Elías Sean Emery Jose Gatell Antonella D'Arminio Monforte Carlo Torti Maurizio Zazzi H. Clifford Lane

OBJECTIVE HIV treatment failure is commonly associated with drug resistance and the selection of a new regimen is often guided by genotypic resistance testing. The interpretation of complex genotypic data poses a major challenge. We have developed artificial neural network (ANN) models that predict virological response to therapy from HIV genotype and other clinical information. Here we compare...

Journal: :Journal of cardiovascular electrophysiology 2013
William W B Chik Michael Anthony Tony Barry Sujitha Thavapalachandran Christine Midekin Jim Pouliopoulos Toon Wei Lim Gopal Sivagangabalan Stuart P Thomas David L Ross Alistair L McEwan Pramesh Kovoor Aravinda Thiagalingam

BACKGROUND Radiofrequency (RF) ablation causes thermal mediated irreversible myocardial necrosis. This study aimed to (i) characterize the thermal characteristics of RF ablation lesions with high spatial resolution using a thermochromic liquid crystal (TLC) myocardial phantom; and (ii) compare the thermochromic lesions with in vivo and in vitro ablation lesions. METHODS AND RESULTS The myocar...

2010
Ana González Suárez Fernando Hornero Enrique J. Berjano

The efficacy of treating atrial fibrillation by RF ablation on the epicardial surface is currently under question due to the presence of epicardial adipose tissue interposed between the ablation electrode and target site (atrial wall). The problem is probably caused by the electrical conductivity of the fat (0.02 S/m) being lower than that of the atrial tissue (0.4-0.6 S/m). Since our objective...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید