نتایج جستجو برای: removal efficiency

تعداد نتایج: 518143  

Abdollahzadeh Sharghi, Elham, Davarpanah, Leila, Taherian, Soma,

Background: Industrial wastewaters containing high amounts of compounds such as sulfate can cause serious risks to human health and environment. Therefore, proposing practical solutions with the lowest cost and the highest efficiency for pollutants removal is of special importance. The purpose of this study is to find a suitable method for treatment wastewater containing very high amounts of...

Mohsen Motevasel, Nematollah Jaafarzadeh, Zahra Heidari,

Background: This research studied the effect of UV light on pentachlorophenol (PCP) removal in the electro-Fenton (EF) process. Methods: PCP was used as the pollutant in this study. The effects of Fenton’s reagent, i.e. hydrogen peroxide concentration, solution pH, and treatment time by EF (EF) and photoelectro-Fenton (PEF) processes, were studied to determine rates of PCP removal. The r...

Ali Asghar Ebrahimi, Amir Hossein Mahvi , Arash Dalvand , Mehdi Mokhtari , Mohammad Hassan Ehrampoush, Mohammad Taghi Ghaneian , Roya Malek Ahmadi,

Introduction: Since some dyes and their metabolites have toxicity and carcinogenicity potential, and are dangerous to the health of different living creatures, discharge of untreated wastewaters containing large concentrations of dye compounds into water resources is one of the important environmental problems. Therefore, in this research, the efficiency of chemical coagulation process was inve...

Journal: :مجله دانشگاه علوم پزشکی شهرکرد 0
عباس خدابخشی abbas khodabakhshi شهرکرد-رحمتیه – دانشکده بهداشت- گروه مهندسی بهداشت محیط محمد مهدی امین amin 2environmental research center, isfahan university of medical sciences, isfahan, iran مرتضی سدهی sedehi 3medical plants research center, shahrekord university of medical sciences, shahrekord, iran.

background and aims: chromium is considered as one of the important environmental pollutants. there is high concentration of chromium in the wastewater of electroplating industries. magnetic iron nanoparticles are used to control and eliminate heavy metals from industrial effluents through the mechanisms of adsorption, ion exchange and electro-static forces. the aim of this study was to evaluat...

Journal: :environmental health engineering and management 0
seyyedali mirshahghassemi center for environmental nanoscience and risk (cenr), department of environmental health sciences, arnold school of public health, university of south carolina, columbia, south carolina 29208, united states behnoush aminzadeh department of environmental engineering, graduate faculty of environment, university of tehran, iran ali torabian department of environmental engineering, graduate faculty of environment, university of tehran, iran kamelia afshinnia center for environmental nanoscience and risk (cenr), department of environmental health sciences, arnold school of public health, university of south carolina, columbia, south carolina 29208, united states

background: car wash waste water contains several contaminants such as organic matter, oil, grease, detergents and phosphates, all of which are harmful for the environment. in this study, the application of electrocoagulation (ec) to treat car wash waste water has been studied, and the operating parameters optimized. the electro-fenton (ef) for further contaminant removal was also investigated....

Aeinjamshid , Kh., M.A. , Dashti ,

The present work has been carried out to investigate the removal efficiency of active oxygen, produced by using APGP cold plasma sterilizer, on the heavy metals of Hg, Pb and Total Suspended Solids in discharge wastewater of Shif shrimp culture complex and Persian Gulf SPF shrimp research center in Bushehr province. The maximum of removal efficiency for Hg and Pb were 66% and 74%, respectively...

Journal: :international archives of health sciences 0
hoseindoost gh. “environment health engineering department, health faculty” and “social determinants of health research center”, kashan university of medical sciences, kashan, iran nasseri s. environment health engineering department, health faculty, tehran university of medical sciences, tehran, iran ehsanifar m. environment health engineering department, health faculty, iran university of medical sciences, tehran, iran sabuhi h. english department, modern languages faculty, isfahan islamic azad university, khorasgan branch, isfahan, iran rabbani d. environment health engineering department, health school, kashan university of medical sciences, pezeshk boulevard, kashan, iran

aims: textile wastewaters are the most important health and environmental problems in kashan. this research was aimed to compare the poly aluminum chloride and chlorinated cuprous efficiency for removal of chemical oxygen demand (cod) and color from kashan textile industries company wastewater. materials & methods: this experimental bench scale study in a batch system was conducted on 20 compos...

2014
Berrin Zeliha Can Recep Boncukcuoglu Alper Erdem Yilmaz Baybars Ali Fil

Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment techn...

Journal: :advances in environmental technology 0
saeed almohammadi department of chemical engineering, mahshahr branch, islamic azad university, mahshahr, iran masoomeh mirzaei department of chemical engineering, mahshahr branch, islamic azad university, mahshahr, iran

in this work, the removal of copper from an aqueous solution by granular activated carbon (gac) in the presence of competitor ions was studied. a batch adsorption was carried out and different parameters such as ph, contact time, initial copper concentration and competitor ions concentration were changed to determine the optimum conditions for adsorption. the optimum ph required for maximum ads...

Membrane technology is one of the few non-pollutant choices when selecting a treatment process. A membrane with suitable pore size can remove almost all pollutants without using any chemicals. In this research, chromium, zinc and lead were removed from synthetic wastewater by a membrane bioreactor. The results showed that by using a membrane bioreactor, the COD removal efficiency was increased ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید