A radiometric assay for gentamicin was compared with an established radioimmunoassay protocol. The coefficients of variation for within-run, day-to-day, and overall runs were consistently higher for the radiometric method as compared with the radioimmunoassay. The coefficient of correlation for 84 patient sera tested by the two methods for gentamicin levels was 0.82. Though less precise, the ra...
Screening examination for maternal, especially serum, is a non-invasive of the fetus’s condition. During pregnancy, screening examinations are performed in women recommended ultrasonography (USG), amniocentesis, or other obstetric interventions. There three markers maternal serum screening: alpha-fetoprotein, human chorionic gonadotropin (hCG), and unconjugated estriol. Maternal alpha-fetoprote...
The 125I-radioimmunoassay for methaqualone in human urine was evaluated by a comparison with newly modified gas-liquid chromatographic and thin-layer chromatographic methods. The statistically significant sensitivity value for the radioimmunoassay was at 2 microgram of methaqualone per liter of urine. The coefficient of variation was 2.88 +/- 0.39% interassay and 2.71 +/- 0.16% intraassay. Ther...
The method used in this report is based on the immunological production of a specific antisera to tnlodothyronine (T3) in rabbits. Conducted at 4 #{176}C, the radioimmunoassay requires three to five days to complete. Hoping to speed this assay, we investigated the influence of time, temperature, and pH. Incubation at 37 #{176}C and pH 8.0 for 30 mm did not deleteriously affect either precision,...
The human PTH radioimmunoassay has been developed by use of bovine PTH and anti-bovine PTH antiserum, both of which were commercially available. The iodination process was modified as to use acid solution resulting in the more stable 125I-PTH. However, the PTH radioimmunoassay employed this antiserum with 125I-bovine PTH revealed that the N-terminal portion of PTH molecule was reactive only sli...
A sensitive radioimmunoassay is described, for measuring isoniazid in therapeutic and subtherapeutic concentrations. This radioimmunoassay was used in an exploratory clinical study to measure, as a function of time, the concentration of this drug in plasma of patients receiving isoniazid therapy.
A radioimmunoassay for bleomycin has been produced using 125l-labeled bleomycin and antisera raised in rabbits against a carbodiimide-catalyzed bleomycin-bovine serum albumin conjugate. 125l-Labeled bleomycin was synthesized by direct iodination of the drug using the chloramine-T technique. The standard curve of the assay was linear on a logit-log plot and the lower limit of sensitivity was 250...
Rabbit antisera highly specific to the bleomycinic acid moiety of bleomycins were obtained by immunizing with a conjugate of copper-complex of bleomycin A5 and bovine serum albumin. These antisera not only reacted with bleomycin A5 but also with other bleomycins such as bleomycin A2, bleomycin B2 and peplomycin. The antisera showed little cross-reactivity with deamido-, depyruvamido- and decarb...