2015
M. Vadrucci R. Cherubini C. De Angelis G. Esposito L. Picardi C. Ronsivalle

The use of radiochromic film (RCF) dosimetry is widely consolidated for applications in photon, electron and proton beams. It offers several advantages, in particular, two-dimensional measurements of dose distributions with high spatial resolution, no post irradiation processing required and no daylight sensitivity. In addition, it shows small LET and energy dependence. GAFCHROMIC® EBT3 films, ...

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2020

2013
David B. Wiant Jonathon A. Terrell Jacqueline M. Maurer Caroline L. Yount Benjamin J. Sintay

Small field dosimetry is a challenging task. The difficulties of small field measurements, particularly stereotactic field size measurements, are highlighted by the large interinstitution variability that can be observed for circular cone collimator commissioning measurements. We believe the best way to improve the consistency of small field measurements is to clearly document and share the res...

2014
Mara Severgnini Mario de Denaro Marina Bortul Cristiana Vidali Aulo Beorchia

Intraoperative electron radiation therapy (IOERT) cannot usually benefit, as conventional external radiotherapy, from software systems of treatment planning based on computed tomography and from common dose verify procedures. For this reason, in vivo film dosimetry (IVFD) proves to be an effective methodology to evaluate the actual radiation dose delivered to the target. A practical method for ...

Journal: :Medical physics 2009
Bruce J Gerbi John A Antolak F Christopher Deibel David S Followill Michael G Herman Patrick D Higgins M Saiful Huq Dimitris N Mihailidis Ellen D Yorke Kenneth R Hogstrom Faiz M Khan

The goal of Task Group 25 (TG-25) of the Radiation Therapy Committee of the American Association of.Physicists in Medicine (AAPM) was to provide a methodology and set of procedures for a medical physicist performing clinical electron beam dosimetry in the nominal energy range of 5-25 MeV. Specifically, the task group recommended procedures for acquiring basic information required for acceptance...

du Plessis, F.C.P., Setilo, I.,

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

Journal: :Medical physics 2007
V Schembri B J M Heijmen

INTRODUCTION AND PURPOSE Conventional x-ray films and radiochromic films have inherent challenges for high precision radiotherapy dosimetry. Here we have investigated basic characteristics of optically stimulated luminescence (OSL) of irradiated films containing carbon-doped aluminum oxide (Al2O3:C) for dosimetry in therapeutic photon and electron beams. MATERIALS AND METHODS The OSL films co...