نتایج جستجو برای: port catheter

تعداد نتایج: 68887  

Journal: :Chang Gung medical journal 2002
Huo-Li Chuang Chen-Nen Chang Jee-Ching Hsu

To make the ventriculo atrial (VA) shunt procedure less invasive and avoid atrial catheter malpositioning, we combined a percutaneous approach with transesophageal echocardiogram (TEE) to monitor the atrial catheter tip. From July 1995 to October 1996, we performed 6 VA shunt procedures by combining these 2 techniques. Except for one patient who had a concomitant Port-A catheter, which obscured...

2013
Satoko Takahara Toshiya Aizaki Yoichi Hatakeyama Shinji Matsushima Kazuhiko Kawamura

A 77-year-old man was admitted with multiple co-morbidities including cerebral infarction, postoperative ossification of the cervical posterior longitudinal ligament, sick sinus syndrome with a cardiac pacemaker inserted from the right subclavian vein, and panperitonitis due to a complicated gastrostomy catheter exchange. The patient developed a critical and rare complication of central venous ...

Journal: :international journal of advanced biological and biomedical research 2014
r. s. kumaravel s. f. maleeka begum b. elayarajah r. rajesh

objective: intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. the present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. methods: in the present st...

Journal: :Indian journal of cancer 2005
Sumit Kapadia Rajiv Parakh Tarun Grover Ajay Yadav

Totally implantable venous devices (TIVD) are increasingly being utilized for venous access for chemotherapy of oncological patients. These devices considerably improve the quality of life of patients requiring long-term chemotherapy. However, despite the great usefulness of TIVDs, their insertion and maintenance is not free of complications. Many early as well as late complications associated ...

2015
Ching-Yang Wu Jui-Ying Fu Ching-Feng Wu Po-Jen Ko Yun-Hen Liu Tsung-Chi Kao Shang-Yueh Yu

Adequate catheter tip location is crucial for functional intravenous port and central venous catheter. Numerous complications were reported because of catheter migration that caused by inadequate tip location. Different guidelines recommend different ideal locations without consensus. Another debate is actual movement of intravascular portion of implanted catheter. From literature review, the c...

Journal: :Journal of vessels and circulation 2022

Background and Aim: Considering that the use of port catheters in long-term treatments quality life (QoL) patients with special conditions, including children, is particularly important, we decided to investigate effect length catheter on duration its performance children. Materials Methods: All files referred Surgery Department Hazrat Masoumeh (PBUH) hospital, who underwent catheterization, we...

Journal: :The Netherlands journal of medicine 2002
D A Koolen H W M van Laarhoven Th Wobbes C J A Punt

BACKGROUND Tunnelled venous catheters improve venous access in cancer patients, but are associated with complications. We retrospectively analysed the outcome of Hickman catheter and Port-A-Cath (PAC) insertion in cancer patients from a department of medical oncology and compared these results with the literature. METHODS The files of patients in whom insertion of a Hickman or PAC was planned...

2014
Cesar Bustos Aitziber Aguinaga Francisco Carmona-Torre Jose Luis Del Pozo

Since the first description in 1982, totally implanted venous access ports have progressively improved patients' quality of life and medical assistance when a medical condition requires the use of long-term venous access. Currently, they are part of the standard medical care for oncohematologic patients. However, apart from mechanical and thrombotic complications, there are also complications a...

Journal: :RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 2016
I Ayx H Goessmann H Hubauer W Uller I Wiesinger C Uhl I Töpel N Zorger

PURPOSE Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. MATERIAL AND METHODS Between 1999 and 2015 38 patients (21 female; 17 male; Age: 17 - 92; Average 54.3 years) underwent an extraction of intravascular dislocated foreign bodies, which were not lost during a radiological intervention. The extracted material included 29 po...

2016
H. Goessmann H. Hubauer W. Uller I. Wiesinger C. Uhl I. Töpel N. Zorger

Correspondence Dr. Isabelle Ayx Radiologie, Barmherzige Brüder Regensburg Prüfeningerstraße 86 93049 Regensburg Germany Tel.: ++ 49/9 41/369943 72 Fax: ++ 49/9 41/3 692523 [email protected] Abstract ▼ Purpose: Evaluation of the technical success rate and complications when retrieving dislocated intravascular foreign bodies. Material and Methods: Between 1999 and 2015 38 patients (21 female; 17 m...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید