نتایج جستجو برای: polymer gel dosimetry

تعداد نتایج: 201784  

Journal: :journal of biomedical physics and engineering 0
m. dehghan master student of physics, department of physics, yazd university, yazd, iran h. mokhtari assistant professor of physics, department of physics, yazd university, yazd, iran f. bouzarjomehri associate professor of medical physics, shahid sadoughi university of medical sciences, yazd, iran

background: over recent decades, modern protocols of external beam radio¬therapy and radiation techniques such as intensity-modulated radiotherapy (imrt) have been developed. these methods are extremely sensitive to errors in treatment delivery, so that it is essential to apply a high resolution 3d dosimetry system that has high sensitivity and is capable of measuring and verifying the complex ...

Journal: :iranian journal of radiation research 0
s.m. abtahi university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran s.m.r. aghamiri university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran h khalafi nuclear science and technology research institute (nstri), tehran, iran f. rahmani university of shahid beheshti, radiation medicine department, p. o. box 19839- 63113, tehran, iran

background: the aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or pmma), a150 plastic and te- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. materials and methods: thermal neutron fluence, photon dose and epithermal neut...

2011
Timothy Olding Oliver Holmes Paul DeJean Kim B. McAuley Ken Nkongchu Giles Santyr L. John Schreiner

This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM)-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparis...

2006

ID: 5462 Title: Advances in Co-60 based Tomotherapy Including Megavoltage CT Purpose: To evaluate the potential for Co-60 based tomotherapy including dose delivery and mega-voltage CT (MVCT). Tomotherapy is a rotational implementation of IMRT that provides highly conformal doses and patient setup verification using MVCT. Current tomotherapy is limited to linear accelerators. This poster present...

Journal: :Journal of Physics: Conference Series 2015

2012
N. Gopishankar S. Vivekanandhan S.S. Kale G.K. Rath S. Senthilkumaran S. Thulkar V. Subramani M.A. Laviraj R.K. Bisht A.K. Mahapatra

This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in...

Journal: :Journal of Physics: Conference Series 2009

Journal: :iranian journal of radiation research 0
s.m. abtahi shahid beheshti university, nuclear engineering faculty, tehran, iran m. shahriari shahid beheshti university, nuclear engineering faculty, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran h. khalafi nuclear science and technology research institute, tehran, iran sh. akhlaghpoor novin medical radiation institute, tehran, iran s. bagheri novin medical radiation institute, tehran, iran

parameters that have to be measured in gel dosimetry. however, the resolution in gel is strongly dependant on gel composition. selection of optimum method in dose response readout and proper values of parameters can result in noise reduction as well as improvement of contrast, and spatial resolution considerably. materials and methods: magica polymer gel dosimeters were manufactured and irradia...

2015
H. Khosravi B. Hashemi S. R. Mahdavi P. Hejazi

BACKGROUND Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. OBJECTIVE The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radioth...

H. Pourbeigi, M.H. Zahmatkesh, Sh. Akhlaghpoor,

Background: Since 1984 MRI gel dosimetry has been introduced as a potential technique for 3D dosimetry. Most of the studies have measured R1 (1/T1) or R2 (1/T2) properties of the gel depending on the gel type. We have studied image intensity change in the Fricke gel by different MRI protocols. Materials and Methods: Gel Dosimeters contain 0.4 mM ferrous sulphate, 1 mM NaCl, 50 mM H2SO4 and 1% b...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید