2013
Zhang Xin Dang Jianwu Liu Min

According to the control requirements of the leaves’ position precision in the multi-leaf collimator, the structure and working principle of the multi-leaf collimator in the conformal radiation therapy apparatus are described. The motor that drives the leaf of the MLC is taken as the control object. The module of the motor has been established. Then the PSO algorithm is used for the parameter o...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1970
S P Tsialas G J Hine

For scintigraphic instruments such as scanners and scintillation cameras, collimatore with greatly dif ferent characteristics have become available during recent years. In general little information is given concerning the performance of focused collimatore to the physician or physicist who has to select the proper collimator for a particular application.! Only the number of holes, the focal le...

Journal: :Nuclear Instruments and Methods in Physics Research 2021

Gamma-ray spectrometry is widely applied in several science fields, and particular non-destructive gamma scanning emission tomography of irradiated nuclear fuel. Often, a collimator used the experimental setup, to selectively interrogate region interest For optimization instrument design, as well for planning measurement campaigns, predictive models transmitted gamma-ray intensity through are n...

Journal: :EJNMMI Physics 2021

Abstract Purpose The quantitative accuracy of Nuclear Medicine images, acquired for both planar and SPECT studies, is influenced by the isotope-collimator combination as well image corrections incorporated in iterative reconstruction process. These factors can be investigated optimised using Monte Carlo simulations. This study aimed to evaluate quantification 123 I with low-energy high resoluti...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1970
J D Bernard R A McDonald J A Nesmith

attached to an external detector system, the thyroid uptake of iodine was measured at 6 and 24 hr. The external detector consisted of a 1Â1⁄4x 1 in. NaI(Tl) scintillation crystal and a flat-field lead collimator. A Lucite extension of the collimator was shaped to fit the neck and assure good geometry with a neck-to crystal distance of 20 cm. A standard neck phantom was used with standard capsul...

2017
Mohammad Javad Tahmasebi Birgani Nahid Chegeni Mohammad Ali Behrooz Marziyeh Bagheri Amir Danyaei Azin Shamsi

INTRODUCTION One of the important input factors in the commissioning of the radiotherapy treatment planning systems is the phantom scatter factor (Sp) which requires the same collimator opening for all radiation fields. In this study, we have proposed an analytical method to overcome this issue. METHODS The measurements were performed using Siemens Primus Plus with photon energy 6 MV for fiel...

2017
Leonard H. Kim Irina Malajovich Meral L. Reyhan Jinyu Xue Joo Han Park

We present an example when profile measurement and modeling of an Elekta Agility multileaf collimator (MLC) had a large effect specifically on arc therapy plan quality assurance (QA) results using ArcCheck. ArcCheck absolute dose measurements of these plans were systematically lower than planned by 3-10%. Failing QA results were seen even with unmodulated static and conformal arcs. Furthermore,...