نتایج جستجو برای: pedaling without occlusion n8

تعداد نتایج: 846323  

2003
Laura Gagliardi Stefano Evangelisti

The HF/3s2pld and MP213s2pld structures, energies and vibrational frequencies were calculated for ten N8 isomers, corresponding to ten analogous CH structures. Comparative calculations using density functional theory (DFT), with a cc-pVTZ basis set, were also performed. All ten structures were found to be local minima on the energy hypersurface at the Hartree-Fock (HF) level, whereas at the sec...

Journal: :Journal of biomechanics 2008
Jeffery W Rankin Richard R Neptune

Previous studies have sought to improve cycling performance by altering various aspects of the pedaling motion using novel crank-pedal mechanisms and non-circular chainrings. However, most designs have been based on empirical data and very few have provided significant improvements in cycling performance. The purpose of this study was to use a theoretical framework that included a detailed musc...

Journal: :Journal of applied physiology 2001
T Muraoka Y Kawakami M Tachi T Fukunaga

Muscle fascicle lengths of vastus lateralis (VL) muscle were measured in five healthy men during slow pedaling to investigate the interaction between muscle fibers and tendon. Subjects cycled at a pedaling rate of 40 rpm (98 W). During exercise, fascicle lengths changed from 91 +/- 7 (SE) to 127 +/- 5 mm. It was suggested that fascicles were on the descending limb of their force-length relation...

1998
J. Robert Ensor Gianpaolo U. Carraro

Peloton is a simulator that creates virtual environments for bicycle rides. Each simulation participant pedals a stationary bicycle that is attached to a local computer through a wheel rotation sensor and a pedaling resistance controller. The local computers are connected to a simulation server by the World Wide Web. Peloton’s virtual environments reproduce sights, sounds, and pedaling resistan...

Journal: :Taiwanese Journal of Obstetrics and Gynecology 2017

Journal: :The European respiratory journal 1996
B Johansen P Giaever F Aspestrand A Kolbenstvedt

Unilateral airway occlusion permits measurement of single lung function. Since the results suggest that the occluded lung influences the mobility of the contralateral hemithorax, we wanted to test this hypothesis. In eight healthy subjects, we measured, using computed tomography, lung parenchymal area and inner rib cage parasagittal and transverse diameters at three different levels and at maxi...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید