نتایج جستجو برای: monte carlo dosimetry
تعداد نتایج: 79689 فیلتر نتایج به سال:
Dose distributions in different models of inhomogeneous phantoms irradiated with 3 19 MeV electron beams have been calculated using DOSXYZnrc/EGSnrc Monte Carlo code. The rectilinear 3D voxel phantoms, relevant for radiotherapy and clinical dosimetry, were built from ICRU soft tissue equivalent material in which was inserted a single layer of bone, lung, air or Titanium. Significant interface e...
Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium co...
PURPOSE GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of...
introduction after the publication of task group number 43 dose calculation formalism by the american association of physicists in medicine (aapm), this method has been known as the most common dose calculation method in brachytherapy treatment planning. in this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
Radionuclide therapy requires patient-specific planning of the absorbed dose to target volumes, in most cases tumours, in order to achieve an expected biological effect, taking into account that the absorbed doses to normal organs and tissues should be kept as low as reasonably achievable. Therefore, the calculation of absorbed doses has to be as accurate as possible. The accuracy depends on th...
We introduce a fast and well-structured package for constructing voxel-based computational phantoms as MCNP(X) input file based on CT DICOM images. Our program which has been implemented under a graphic user inter-face provides several basic image processing tools for manipulating images. The MCNP materials are interpreted from the CT numbers of DICOM images. Two modes of phantom creation have ...
In calculations for the Leksell Gamma Knife, GammaPlan employs a tissue equivalent material without the presence of a skull bone, while dosimetry work is based on a polystyrene phantom. The compatibility of these dose distributions is uncertain. The Monte Carlo technique was employed to determine the radial dose distributions from a single 14 mm collimator helmet in 160 mm diam phantoms with di...
Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...
Dosimetry calculations characterizing the spatial variation of the energy deposited by the slowing and stopping of energetic electrons are reported and compared with experimental measurements from an electron microbeam facility. The computations involve event-by-event, detailed-histories Monte Carlo simulations of low-energy electrons interacting in water vapor. Simulations of electron tracks w...
The solid-state nuclear track detector CR-39 is widely used as a detecting mechanism in physics experiments as well as for industrial purposes such as neutron dosimetry and radon detection. The upper limit of detectable charged-particle fluence on CR-39 is set by physical overlapping or ‘pulse pileup’ of particle tracks on the surface. In the low-overlap regime the overlapping fraction of track...