Recently, flood damage has become a social problem owing to unexperienced weather conditions arising from climate change. An immediate response heavy rain is important for the mitigation of economic losses and also rapid recovery. Spatiotemporal precipitation forecasts may enhance accuracy dam inflow prediction, more than 6 h forward mitigation. However, ordinary ConvLSTM limitation predictable...
The MCNP Monte Carlo radiation transport code was used for calculation of scatter distribution and scatter-toprimary ratio (SPR) for different tube voltages, phantom thicknesses and field size in diagnostic radiology. Subsequently, the effect of grid’s design parameters such as strip density, grid ratio, interspace material and lead-tointerspace ratio on scatter rejection was investigated by ca...
background: lead-based radiation shields are widely used in radiology departments to protect both workers and patients from any unnecessary exposure to ionizing radiation. recently there has been a great deal of concern expressed about the toxicity of lead. human lead toxicity is well documented. in that light, production of environmentally-friendly lead-free radiation shields with less weight ...
background: the dose rate distribution delivered by a low dose rate 137cs pellet source, a spherical source used within the source trains of the selectron gynecological brachytherapy system, was investigated using the mcnp4c monte carlo code. materials and methods: the calculations were performed in both water and plexiglas and the absolute dose rate distribution for a single pellet source and ...
background: prompt gamma neutron activation analysis (pgnaa) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. also it is a valuable diagnostic tool for total body elemental measurements. 252cf and 241am-be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...
introduction one of the best methods in the diagnosis and control of breast cancer is mammography. the importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. the purpose of this article was to calculate the x-ray spectrum in a mammography system with monte carlo codes, including mcnpx and mcnp5...
مقدمه: دزیمتری چشمه های براکی تراپی طبق پروتکل tg-43u1 در محیط آب اطراف چشمه انجام می شود. برای رسیدن به یک نتیجه مناسب درمان، استفاده از ماده آب برای همه بافت های بدن می تواند یکی از منابع خطا در رسانیدن دز صحیح به تومور مورد نظر داشته باشد؛ از این رو در این مطالعه به تعیین پارامترهای دزیمتری بافت های متفاوت چربی با چگالی gr/cm3 95/0 و ماهیچه با چگالی gr/cm3 05/1 پرداخته ایم تا با مقایسه آن ها...
Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...