نتایج جستجو برای: magic f polymer gel dosimeters

تعداد نتایج: 505330  

Journal: :Physics in medicine and biology 2009
Stephen G Bosi Saxby Brown Sarvenaz Sarabipour Yves De Deene Clive Baldock

A gelatin phantom containing an optically scattering funnel-shaped region of elevated optical density (OD) was used to examine light-scattering-induced artefacts in a cone-beam optical CT scanner used for gel dosimetry. To simulate polymer gel dosimeters, the opacity was introduced by adding a colloidal scatterer to the gelatin. Scatter results in an underestimate of OD (hence dose). In line pr...

An H-magic labeling in a H-decomposable graph G is a bijection f : V (G) ∪ E(G) → {1, 2, ..., p + q} such that for every copy H in the decomposition, ΣνεV(H) f(v) +  ΣeεE(H) f(e) is constant. f is said to be H-E-super magic if f(E(G)) = {1, 2, · · · , q}. A family of subgraphs H1,H2, · · · ,Hh of G is a mixed cycle-decomposition of G if every subgraph Hi is isomorphic to some cycle Ck, for k ≥ ...

G. Marimuthu, S. Stalin Kumar

An H-magic labeling in a H-decomposable graph G is a bijection f : V (G) ∪ E(G) → {1, 2, ..., p + q} such that for every copy H in the decomposition, ∑νεV (H) f(v) + ∑νεE (H) f(e) is constant. f is said to be H-E-super magic if f(E(G)) = {1, 2, · · · , q}. A family of subgraphs H1,H2, · · · ,Hh of G is a mixed cycle-decomposition of G if every subgraph Hi is isomorphic to some cycle Ck, for k ≥...

Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...

Journal: :International Journal of Molecular Sciences 2008
Akira Kakugo Kazuhiro Shikinaka Jian Ping Gong

We present a soft bio-machine constructed from biological motors (actin/myosin). We have found that chemically cross-linked polymer-actin complex gel filaments can move on myosin coated surfaces with a velocity as high as that of native F-actin, by coupling to ATP hydrolysis. Additionally, it is shown that the velocity of polymer-actin complex gel depends on the species of polycations binding t...

Journal: :journal of algorithms and computation 0
p. jeyanthi 2research center, department of mathematics, aditanar college for women, tiruchendur - 628 216, india n. angel benseera department of mathematics, sri enakshi government arts college for women (autonomous), madurai - 625 002, india.

a graph g is said to have a totally magic cordial labeling with constant c if there exists a mapping f : v (g) ∪ e(g) → {0, 1} such that f(a) + f(b) + f(ab) ≡ c (mod 2) for all ab ∈ e(g) and |nf (0) − nf (1)| ≤ 1, where nf (i) (i = 0, 1) is the sum of the number of vertices and edges with label i. in this paper, we give a necessary condition for an odd graph to be not totally magic cordial and ...

2017
Yoichi Watanabe Leighton Warmington N Gopishankar

Accurate dose measurement tools are needed to evaluate the radiation dose delivered to patients by using modern and sophisticated radiation therapy techniques. However, the adequate tools which enable us to directly measure the dose distributions in three-dimensional (3D) space are not commonly available. One such 3D dose measurement device is the polymer-based dosimeter, which changes the mate...

Journal: :Brazilian Journal of Radiation Sciences 2022

The present work compared the relative absorbed dose of some dosimetric materials, for energies 250 kV and 6 MV, using PENELOPE MNCPX codes. composition each material GD-301, TLD-100, MAGIC, MAGAT were simulated disposed in a phantom filled with water following reference conditions recommended by TRS-398 protocol. Percentage depth was used as parameter comparison. Since obtained results both co...

2018
Chun-Chao Chuang Jay Wu

Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensitivity profile (SSP) for multiple detector CT (MDCT). Magnetic resonance imaging (MRI) was perfor...

Journal: :journal of algorithms and computation 0
g. marimuthu department of mathematics, the madura college, madurai -625 011, tamilnadu, india s. stalin kumar department of mathematics, the american college, madurai - 625 002, tamilnadu,india

an h-magic labeling in a h-decomposable graph g is a bijection f : v (g) ∪ e(g) → {1, 2, ..., p + q} such that for every copy h in the decomposition, σνεv(h) f(v) +  σeεe(h) f(e) is constant. f is said to be h-e-super magic if f(e(g)) = {1, 2, · · · , q}. a family of subgraphs h1,h2, · · · ,hh of g is a mixed cycle-decomposition of g if every subgraph hi is isomorphic to some cycle ck, for k ≥ ...

نمودار تعداد نتایج جستجو در هر سال