نتایج جستجو برای: isocenter

تعداد نتایج: 707  

2010
Tarek Halabi Bruce Faddegon

We design a practical procedure for measuring translational and rotational misalignment of graticule with collimator axis of rotation and collimator jaws, respectively. The procedure's quantitative results are accurate to less than 0.2 mm (at isocenter) and do not assume alignment of radiation focal spot with collimator axis of rotation. When provided with these quantitative results, the manufa...

Journal: :International Journal of Radiation Oncology*Biology*Physics 2015

Journal: :International Journal of Radiation Oncology*Biology*Physics 2016

Journal: :International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2016

Journal: :iranian journal of radiation research 0
h. acar selcuk university, faculty of medicine, department of radiation oncology, konya, turkey g. yavas selcuk university, faculty of medicine, department of radiation oncology, konya, turkey c. yavas konya training and research hospital, department of radiation oncology, konya, turkey

background: broca’s and wernicke’s areas, which are important language areas of brain, are commonly irradiated in patients with right frontal lobe glioblastomamultiforme (gbm). we aimed to compare two different treatment planning techniques in terms of the doses in the broca’s and wernicke’s areas for the patients with right frontal gbm. materials and methods: two different treatment planning t...

M. Keshtkar, M. Saeb, N. Rostampour, P. Shokrani, S. Jafari, T. Almasi,

Background: Skyshine describes the radiation scattered by the atmosphere above a LINAC facility to a point on the ground. The aim of this study was to measure the skyshine photon dose rates from two different (9 MV and 18 MV) medical linear accelerators. Materials and Methods: The photon beam was directed upward (180° gantry position), with a maximum photon field size (40 × 40 cm2) at the isoce...

A.R. Khoshbin Khoshnazar, M.T. Bahreyni Toossi,

Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...

Journal: :Frontiers in Physics 2022

The Australian MRI-Linac prototype radiotherapy system has been shown to generate significant entry skin or surface dose increases. This arises from electron contamination focusing toward the isocenter caused by 1 T MRI field being in-line with x-ray beam. aim of this study is present accurate Monte Carlo modeling these changes and compare them previous experimental measurements. Accurate will ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید