نتایج جستجو برای: inflow control device icd
تعداد نتایج: 1924623 فیلتر نتایج به سال:
BACKGROUND Implantable cardioverter defibrillators (ICDs) are indeed beneficial in selected patients as evidenced by multiple large randomized controlled trials (RCTs) since 1980. A systematic method for stratification of patients and hospital-wide criteria/guidelines to ascertain appropriate device implantation became necessary. METHODS Major ICD/CRT (cardiac resynchronization therapy) clini...
BACKGROUND The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. METHODS One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All p...
Short QT syndrome carries the risk for inappropriate therapies using transvenous ICD because of overdetection of the ample T wave. SQT syndrome may also benefit from subcutaneous ICD, although additional cases are needed to affirm the safety of such device in this setting.
The ventricular tachycardia (VT) monitoring zone in implantable cardioverter defibrillators (ICDs) is usually programmed to detect slow VTs. However, it is not well known whether programming this zone can affect the ICD arrhythmia redetection or confirmation criteria. We report two cases of inappropriate ICD shocks due to the programming of a slow VT monitoring zone in the same device model.
INTRODUCTION AND OBJECTIVES Although implantable cardioverter-defibrillators (ICDs) are recommended for high-risk patients with hypertrophic cardiomyopathy (HCM), there is no agreement on their general use. Moreover, little information is available on ICD use in this setting in Spain. Our aims were to describe the characteristics of HCM patients who received ICDs at three hospitals in Spain, an...
BACKGROUND Despite the frequent occurrence of bacteremia due to gram-negative organisms in patients with underlying permanent pacemakers (PPMs) or implantable cardioverter defibrillators (ICDs), the outcome and treatment of these patients has received scant attention. In patients with PPMs or ICDs who have Staphylococcus aureus bacteremia, 45% have PPM/ICD infection. METHODS We conducted a re...
BACKGROUND We are presenting a case report on an unreported and unusual cutaneous manifestation of chronic lymphocytic leukemia in a patient with an implantable cardioverter-defibrillator (ICD). CASE PRESENTATION A 65-year-old man with a history of chronic lymphocytic leukemia (CLL), previously treated with chlorambucil, was referred in October 2013 for extraction of a single chamber ICD due ...
Breast cancer has become common in developing and developed countries. Alarming increase in this disease as a leading cause of death in women is a concern of all. Despite the significant improvements in the management of breast cancer, the survival rate is not more than 20% - 25%. For this study, MDA-MB231 cell line was used and the effect of ICD-85 (biologically active peptides from venomous ...
Proclemer et al. report real-life data from a large cohort of more than 35 000 patients treated with implantable cardioverter defibrillator (ICD) therapy during the period 2005–07. These data document that the use of ICD treatment as primary prevention increased markedly during this period, in absolute numbers more than 50% from 2005 to 2007. In contrast, the number of patients treated with an ...
Video capsule endoscopy (VCE) is a useful diagnostic tool in patients with unknown blood loss, particularly when there is a high suspicion of small bowel disease, but because of its use of radio frequency, it is relatively contraindicated in patients with a cardiac device. We report the case of a patient with an implantable cardiac defibrillator (ICD) who underwent VCE because of anaemia and pr...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید