نتایج جستجو برای: hybrid phantoms

تعداد نتایج: 202911  

2009
James A. Zagzebski James Kofler

Components of an Ultrasound Quality Assurance Program 257 Quality Assurance and Preventive Maintenance 257 Tissue-Mimicking Phantoms 257 Tissue Properties Represented in Phantoms 257 Typical Quality Assurance Phantom Design 257 Cautions About Phantom Desiccation 258 Basic Quality Control Tests 259 Visual Inspection 259 Transducer Choice 259 System Sensitivity 260 Photography and Gray-Scale Hard...

Journal: :Ultrasonic imaging 2013
Alexander D Pawlicki William D O'Brien

Estimating total ultrasound attenuation from backscatter data is essential in the field of quantitative ultrasound (QUS) because of the need to compensate for attenuation when estimating the backscatter coefficient and QUS parameters. This work uses a reference phantom method of attenuation estimation to create a spatial map of attenuation slope (AS) from backscatter radio-frequency (RF) data o...

2011
Manzoor Ahmad Sanaz Alali Anthony Kim Michael F. G. Wood Masroor Ikram I. Alex Vitkin

We here investigate polarimetric behavior of thick samples of porcine liver, Intralipid, and microsphere-based tissue phantoms whose absorption and scattering properties are matched. Using polarized light we measured reflection mode Mueller matrices and derived linear/circular/total depolarization rates, based on polar decomposition. According to our results, phantoms exhibit greater depolariza...

2014
Liang Mei Gabriel Somesfalean Sune Svanberg

In the present work, fiber-based frequency-modulated light scattering interferometry (FMLSI) is developed and employed for studies of optical properties and dynamics in liquid phantoms made from Intralipid(®). The fiber-based FMLSI system retrieves the optical properties by examining the intensity fluctuations through the turbid medium in a heterodyne detection scheme using a continuous-wave fr...

Journal: :Magnetic Resonance in Medicine 2021

Purpose Chemical shift‐encoded MRI (CSE‐MRI) is well‐established to quantify proton density fat fraction (PDFF) as a quantitative biomarker of hepatic steatosis. However, temperature known bias PDFF estimation in phantom studies. In this study, strategies were developed and evaluated correct for the effects on through simulations, temperature‐controlled experiments, multi‐center, multi‐vendor s...

Journal: :Journal of nuclear medicine technology 2015
Maryam Jessop John D Thompson Joanne Coward Audun Sanderud José Jorge Martijn de Groot Luís Lança Peter Hogg

UNLABELLED Incidental findings on low-dose CT images obtained during hybrid imaging are an increasing phenomenon as CT technology advances. Understanding the diagnostic value of incidental findings along with the technical limitations is important when reporting image results and recommending follow-up, which may result in an additional radiation dose from further diagnostic imaging and an incr...

2010
aniel M. de Bruin G. van Leeuwen

irk J. Faber niversity of Amsterdam cademic Medical Center epartment of Biomedical Engineering and Physics and pththalmology Department msterdam, 1100 DE Netherlands Abstract. Current innovations in optical imaging, measurement techniques, and data analysis algorithms express the need for reliable testing and comparison methods. We present the design and characterization of silicone elastomer-b...

Journal: :Journal of biomedical optics 2010
Daniel M de Bruin Rolf H Bremmer Vitali M Kodach Roy de Kinkelder Jan van Marle Ton G van Leeuwen Dirk J Faber

Current innovations in optical imaging, measurement techniques, and data analysis algorithms express the need for reliable testing and comparison methods. We present the design and characterization of silicone elastomer-based optical phantoms. Absorption is included by adding a green dye and scattering by adding TiO(2) or SiO(2) particles. Optical coherence tomography measurements demonstrate a...

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

Journal: :Journal of biomedical physics & engineering 2023

Background: Methods for segmentation, i.e., Full-segmentation (FS) and Segmentation-rotation (SR), are proposed maintaining Computed Tomography (CT) number linearity. However, their effectiveness has not yet been tested against noise.Objective: This study aimed to evaluate the influence of noise on accuracy CT linearity FS SR methods American College Radiology (ACR) computational phantoms.Mater...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید