نتایج جستجو برای: homogenous liquid liquid microextraction

تعداد نتایج: 229754  

2017
Abuzar Kabir Marcello Locatelli Halil Ibrahim Ulusoy

Sample preparation has been recognized as a major step in the chemical analysis workflow. As such, substantial efforts have been made in recent years to simplify the overall sample preparation process. Major focusses of these efforts have included miniaturization of the extraction device; minimizing/eliminating toxic and hazardous organic solvent consumption; eliminating sample pre-treatment an...

In this paper, a simple dispersive liquid-liquid microextraction for the extraction and pre-concentration of formaldehyde in seawater samples followed with spectrophotometric is proposed. Formaldehyde was derivatized in situ with acetyl acetone in the presence of ammonium acetate in a single step. Then it was collected into a mixture of ethanol (disperser solvent) and chloroform (extracting...

2015
Şerife Saçmacı Şenol Kartal Gülçin Kalkan

A new dispersive liquid–liquid microextraction separation/preconcentration procedure as a rapid sample-preparation technique is proposed for detection of ultra trace amounts of Au(III) in various media by flame atomic absorption spectrometry using 1,5-diphenyl-1,3,5-pentanetrione as chelating agent. Carbon tetrachloride and methanol were used as extraction and dispersive solvents, respectively....

The present research describes the use of directly suspended drop microextraction and air-assisted dispersive liquid-liquid microextraction method coupled with UV-Vis spectrophotometer for the analysis of doxepin in water and biological samples. Several important parameters which influence the extraction efficiencies of these two microextraction methods, such as the kind of extracting solven...

Journal: Nanochemistry Research 2017

A new, sensitive and fast dispersive liquid-liquid microextraction (DLLME) coupled with micro-solid phase extraction (μ-SPE) was developed for determination of zearalenone (ZEN) in wheat samples. The DLLME was performed using acetonitrile/water (80:20 v/v) as the disperser solvent and 1-octanol as the extracting solvent.  The acetonitrile/water (80:20 v/v) solvent was also used to extract ZEN f...

Background: Imatinib is an antineoplastic agent acting as a tyrosine kinase inhibitor to treat cancer such as lymphoblastic leukemia. The dosage of the anticancer drugs plays a critical role in the survival of the patients. For this reason, the patient's plasma and urine samples should be monitored to obtain the necessary information regarding the toxicity of the drug. In this study, the applic...

Darya Shyrina, Mahboob Nemati, Mozhgan Mojkar, Pouya Arabkhani, Vahid Safavizadeh,

Background: Aflatoxin B1 is a secondary toxic metabolite produced by several aspergillus species. This study was conducted to determine the presence of aflatoxin in tomato paste samples. Methods: A total of 30 tomato pastes were analyzed for Aflatoxin B1 contamination via HPLC-FLD. Analyte extraction was done by dispersive liquid-liquid microextraction. Results: The limit of detection (LOD) and...

2016
Li Yan

A method for simultaneous determination of nine sulfonylurea herbicides in water and soil samples with solvent demulsification-dispersive liquid-liquid microextraction based on solidification of floating organic drop coupled with high perfomence liquid chromatography was established. 120 μL of 1-dodecanol as extractant and 400 μL of methanol as dispersing reagent were injected into the sample s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید