نتایج جستجو برای: high flux dialyzer
تعداد نتایج: 2123502 فیلتر نتایج به سال:
BACKGROUND Diffusive clearance depends on blood and dialysate flow rates and the overall mass transfer area coefficient (K(o)A) of the dialyzer. Although K(o)A should be constant for a given dialyzer, urea K(o)A has been reported to vary with dialysate flow rate possibly because of improvements in flow distribution. This study examined the dependence of K(o)A for urea, phosphate and β(2)-microg...
Abstract Introduction Inflammation in patients with ESRD undergoing HD is an increasing concern for physicians and has been related to increase the rates of morbidity mortality. Interestingly, conventional have frequent infections a suboptimal response vaccines; this probably immune inflammatory disorder associated either uremia and/or nutritional status. In addition CRP, which seems be most im...
Axial field flux switching motor with sandwiched permanent magnet (AFFSSPM) is a novel of flux switching motor. Based on the vector control method, the mathematical model of the AFFSSPM is derived and the operating performance of the AFFSSPM in the overall operating region is investigated.A novel control method for the AFFSSPM drive system, including the id =0, maximum torque per ampere, consta...
The elimination rate of iohexol, a non-ionic contrast medium, from the blood by hemodialysis, and the elimination rate of iohexol by a dialyzer were studied in 15 patients with chronic renal dysfunction who required angiography or enhanced CT. The elimination rate of iohexol was 19.8% at 15 min after the start of hemodialysis, 30.6% after 30 min, 44.2% after 1 hour, 62.1% after 2 hours and 72.9...
In this study, the ultrafiltration membrane for humic substance removal was prepared by blending polysulfone with a high concentration of PEG400 as additives. The influences of the additive to the fouling resistance capability and humic substances rejection of the polysulfone membrane were investigated. The addition of 35%wt of PEG400 concentration improved the pure water flux up to 200, but re...
Background: Miniature neutron sources with high neutron flux have abundant applications in medicine, industry and researches. The most important general characteristic of miniature neutron sources is their diameter which is 3mm in average. In this research, we have surveyed and designed an Am-Be miniature neutron source fabrication. Materials and Methods: This investigation resulted in creation...
The frequency of hemodialysis-associated hemorrhage was studied prospectively in two successive, parallel, heparin-controlled studies using epoprostenol (PGI2; average dose, 4.1 ng/kg.min) as the sole antithrombotic agent. Sixty-three patients with active or recently active bleeding underwent 163 hemodialysis treatments in each of which prospective bleeding risk was assessed. PGI2 was associate...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید