نتایج جستجو برای: heavy silicone oil

تعداد نتایج: 269067  

2003

Silicone based oil is heated in the boiler of the diffusion pump and the vaporized oil rises in the central tower and streams out of directional flutes directed downward in the pump throat. This allows air molecules to dissolve in the gaseous oil (gas dissolved in gas). As the oil-air mixture cools (due to water cooling coils wrapped around the pump throat) the oil condenses and returns to liqu...

Journal: :Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye 2012
Mahesh P Shanmugam Rajesh Ramanjulu R Madhu Kumar C K Minija

Silicone oil migration into the subretinal space following vitreoretinal surgery may occur in complex cases of retinal detachment with proliferative vitreoretinopathy. This complication prevents achievement of the primary goal (ie, to attach the retina) and fails to provide the internal tamponade, leading to a permanent decrease in visual acuity. Successful and complete removal of the subretina...

Journal: :The British journal of ophthalmology 2004
R H Y Asaria C H Kon C Bunce C S Sethi G A Limb P T Khaw G W Aylward D G Charteris

AIM To determine whether silicone oil concentrates protein and growth factors in the retro-oil fluid. METHODS A laboratory analysis of intraocular fluid and vitreous specimens obtained from patients undergoing removal of silicone oil, revision vitrectomy, or primary vitrectomy for macular hole, proliferative vitreoretinopathy (PVR), or retinal detachment. Patients were prospectively recruited...

2004
R H Y Asaria C H Kon C Bunce C S Sethi G A Limb P T Khaw G W Aylward D G Charteris David Charteris

Aim: To determine whether silicone oil concentrates protein and growth factors in the retro-oil fluid. Methods: A laboratory analysis of intraocular fluid and vitreous specimens obtained from patients undergoing removal of silicone oil, revision vitrectomy, or primary vitrectomy for macular hole, proliferative vitreoretinopathy (PVR), or retinal detachment. Patients were prospectively recruited...

2015
Thomas Laube Claudia Brockmann Norbert Bornfeld

OBJECTIVE To describe options for vitreoretinal surgery in the management of massive suprachoroidal hemorrhage (SCH). METHODS Visual acuity (VA), ocular findings, timing of surgical intervention, surgical procedures, and outcomes of four patients diagnosed with massive SCH and admitted to the University Eye Clinic Essen were reviewed retrospectively. RESULTS Four eyes of four patients (mean...

2010
Mario R Romano Martina Angi Vito Romano Francesco Parmeggiani Claudio Campa Xavier Valldeperas Ciro Costagliola

OBJECTIVE To compare the effects of standard silicone oil 5700 (SSO) and heavy silicone oil (HSO) such as Densiron(®) 68 on intraocular pressure (IOP). MATERIALS AND METHODS Retrospective case series including 180 eyes (105 treated with SSO and 75 with HSO). IOP was measured before surgery, 1 day after, and then at 1-, 3-, 6-, and 12-month follow-ups. RESULTS In the SSO group, a significant...

Journal: :Journal of hazardous materials 2010
Guillermo Quijano José Rocha-Ríos Maria Hernández Santiago Villaverde Sergio Revah Raúl Muñoz Frédéric Thalasso

The effect of liquid and solid transfer vectors (silicone oil and Desmopan, respectively) on the gaseous interfacial area (a(g)) was evaluated in a two-phase partitioning bioreactor (TPPB) using fresh mineral salt medium and the cultivation broth of a toluene degradation culture (Pseudomonas putida DOT-T1E cultures continuously cultivated with and without silicone oil at low toluene loading rat...

Journal: :Arquivos brasileiros de oftalmologia 2005
Rogil José de Almeida Torres Andréa Luchini Rogério João de Almeida Torres Fernando César Abib Reginaldo Antônio de Almeida Torres

The objective of this report is to demonstrate the effectiveness of an iris prosthesis to treat a refractory glaucoma induced by silicone oil in the anterior chamber. This case is about a patient who suffered a trauma caused by firearm shrapnel. A vitreous-retinal surgery was performed to remove intraocular foreign matter and to realign the retina that was detached. Due to the partial traumatic...

Journal: :Journal of biotechnology 2012
María Montes María C Veiga Christian Kennes

Recently, research on the use of binary aqueous-organic liquid phase systems for the treatment of polluted air has significantly increased. This paper reports the removal of α-pinene from a waste air stream in a continuous stirred tank bioreactor (CSTB), using either a single-liquid aqueous phase or a mixed aqueous-organic liquid phase. The influence of gas flow rate, load and pollutant concent...

2016
Nisar Ahmed Siyal Lakhani Das Hargun Shahid Wahab

OBJECTIVE To study the outcomes of passive removal of silicone oil by 23 Gauge Transconjunctival Sutureless Vitrectomy System. METHODS This prospective, consecutive case series study was conducted at Ophthalmology Department Unit I, Dow University of Health Sciences, Civil Hospital Karachi from January 2011 to December 2014. Only psuedophakic eyes with silicone oil temponade were selected. Ma...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید