نتایج جستجو برای: harmonic filters
تعداد نتایج: 90739 فیلتر نتایج به سال:
Recently wide spread of power electronic equipment has caused an increase of the harmonic disturbances in the power systems. The nonlinear loads draw harmonic and reactive power components of current from ac mains. Current harmonics generated by nonlinear loads such as adjustable speed drives, static power supplies and UPS. Thus a perfect compensator is required to avoid the consequences due to...
Increasing use of variable speed drives in industry causes harmonic proliferation in industrial power distribution supply system. Harmonic currents generated by the variable speed drives interact with power system impedance to give rise to harmonic voltage distortion. Thus it is essential to analyze, evaluate and introduce appropriate mitigation techniques for harmonic reduction in the power sy...
Coded excitation methods offer the potential for improving the SNR without increasing the peak transmitted power and without sacrificing resolution. Our study examines the potential application of coded waveforms, specifically FM chirps, in harmonic imaging. Such a system, in which nonlinear echoes from tissue are used to form the image, requires the extraction and compression of the second har...
The Nigerian electric power industry is facing a lot of challenges. From generation to distribution, the system's reliability far below expectation. Modeling hybrid active filters with Matlab/Simulink environment mitigate harmonics stress by non-linear load focus. was connected directly supply, modeled filter in parallel distribution network. consists passive and an system. used low order harmo...
I INTRODUCTION Advancement in technology of semiconductor devices has led to a revolution in electronic technology over the past decade. However rise in the power quality (PQ) problem is due to power equipments which include adjustable-speed motor drives (ASDs), electronic power supplies, direct current (DC) motor drives, battery chargers, electronic ballasts. The distortion in current is due t...
The firing angle control of thyristor full wave ac-dc converters to set the desired DC bus voltage in Uninterruptible Power Supply (UPS) systems have drawbacks of pulsating input current, high harmonic content, low pf, low efficiency and large size of inductors and filters. International standards impose several constraints concerning the electric power quality and harmonic content of the line ...
This paper presents a fuzzy logic, PI, average current controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Va...
Estimating the fundamental frequency and harmonic parameters is basic for signal modelling in a power supply system. Differing from the existing parameter estimation algorithms either in power quality monitoring or in harmonic compensation, the proposed algorithm enables a simultaneous estimation of the fundamental frequency, the amplitudes and phases of harmonic waves. A pure sinusoid is obtai...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید