نتایج جستجو برای: gamma dose rate

تعداد نتایج: 1332210  

2009
Seungwoo Park Haijo Jung Kum Bae Kim Sang Hun Shin Kihong Son Chang Yeol Lee Young Hoon Ji

Gamma irradiation device using Cs-137 have been widely utilized to the irradiation of cell, blood, and animal, and the dose measurement and education. The Gammacell 3000 Elan (Nordion International, Kanata, Ontario, Canada) irradiator was installed in 2003 with Cs-137 and dose rate of 3.2 Gy/min. And the BioBeam 8000 (Gamma-Service Medical GmbH, Leipzig, Germany) irradiator was installed in 200...

2016
Ned Xoubi Primoz Pelicon

In nuclear experimental, training and teaching laboratories such as a subcritical reactor facility, huge measures of external radiation doses could be caused by neutron and gamma radiation. It becomes imperative to place the health and safety of staff and students in the reactor facility under proper scrutiny. The protection of these individuals against ionization radiation is facilitated by ex...

2017
Anne Graupner Dag M. Eide Dag A. Brede Michele Ellender Elisabeth Lindbo Hansen Deborah H. Oughton Simon D. Bouffler Gunnar Brunborg Ann Karin Olsen

Risk estimates for radiation-induced cancer in humans are based on epidemiological data largely drawn from the Japanese atomic bomb survivor studies, which received an acute high dose rate (HDR) ionising radiation. Limited knowledge exists about the effects of chronic low dose rate (LDR) exposure, particularly with respect to the application of the dose and dose rate effectiveness factor. As pa...

Journal: :iranian journal of fisheries science 0
d. boreyri m. afsharnasab a.a. motalebi a. haghigh

in this research, white spot syndrome virus (wssv) with 105.4ld50.ml-1 inactivated with gamma irradiation at a dose rate of 14-15 kgy.sec-1 was used as a vaccine. three hundred and sixty shrimp of litopenaeus vannamei, medium body weight (mbw) 1.0±0.17g), were prepared and experimentally exposed. they were distributed among four groups, inclusing vaccinated-virus exposed (t1), vaccinated-nonvir...

Journal: :journal of biomedical physics and engineering 0
f. bouzarjomehri department of medical physics, shahid sadoughi university of medical sciences, yazd, iran v. tsapaki department of medical physics, konstantopoulio hospital, nea ionia, athens, greece

introduction: active personal dosimeters (apds) are well accepted as useful and reliable instruments for individual dosimetry measurements. apds have many advantages compared with passive dosimeters for individual external radiation dose assessments. in routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. so, ...

M. T. Kolo, M. U. Khandaker, W. H. B. Abdullah, Y. M. Amin,

Background: Human activities such as mining enhance the radioactivity levels above normal background which can lead to an incremental increase in the radiation risk to the population. Materials and Methods: 20 tailing enriched soil samples collected around Maiganga coal mine, Gombe, Northeast Nigeria were assessed for their 226Ra, 232Th and 40K contents using HPGe gamma-ray detector. Results: T...

2000
T. Nishikawa

The EGS4 (Electron Gamma Shower, Version 4) Monte Carlo simulation code is used to calculate the conversion factors of the radon daughter quantity accumulated on the ground surface to the environmental gamma radiation dose rate with considering the actual geographical conditions. When the precipitation rate is low, the time variation of the environmental gamma radiation dose rate estimated from...

2013
Yunfei Huang Ryan T. Flynn R. Alfredo C. Siochi John E. Bayouth

The clinical application of the flattening filter-free photon beam (FFF) has enjoyed greater use due to its advantage of reduced treatment time because of the increased dose rate. Its unique beam characteristics, along with the very high-dose rate, require a thorough knowledge of the capability and accuracy in FFF beam modeling, planning, and delivery. This work verifies the feasibility of mode...

2017
Jeffrey E. Snyder Ryan T. Flynn Daniel E. Hyer

The accurate delivery of respiratory-gated volumetric modulated arc therapy (VMAT) treatment plans presents a challenge since the gantry rotation and collimator leaves must be repeatedly stopped and set into motion during each breathing cycle. In this study, we present the commissioning process for an Anzai gating system (AZ-733VI) on an Elekta Versa HD linear accelerator and make recommendatio...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه علامه طباطبایی - دانشکده اقتصاد 1391

reinsurance is widely recognized as an important instrument in the capital management of an insurance company as well as its risk management tool. this thesis is intended to determine premium rates for different types of reinsurance policies. also, given the fact that the reinsurance coverage of every company depends upon its reserves, so different types of reserves and the method of their calc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید