نتایج جستجو برای: gafchromic film
تعداد نتایج: 90975 فیلتر نتایج به سال:
Purpose: This study investigated whether real-time variable shape tungsten rubber (STR) could be applied for nail radiation protection in total skin electron beam (TSEB) therapy. Methods: Simulated finger phantoms were made from syringes filled with physiological saline of volumes 5, 10, 20, and 30 ml (inner diameters 14.1, 17.0, 21.7, 25.3 mm, respectively). Gafchromic film was to the phantom,...
PURPOSE This work investigates the dose-response curves of GAFCHROMIC(®) EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. METHODS Monochromatic beams...
PURPOSE Bombarding high-Z material with x-ray radiation releases Auger electrons and Coster-Kronig electrons, along with deeper penetrating fluorescent x-rays and photoelectrons. The Auger and Coster-Kronig electron penetration distance is on the order of nanometers to micrometers in water or tissue, creating a large dose enhancement accompanied by a RBE greater than 1 at the cellular level. Th...
PURPOSE To evaluate the uncertainties and characteristics of radiochromic film-based dosimetry system using the EBT3 model Gafchromic(®) film in therapy photon, electron and proton beams. MATERIAL AND METHODS EBT3 films were read using an EPSON Expression 10000XL/PRO scanner. They were irradiated in five beams, an Elekta SL25 6 MV and 18 MV photon beam, an IBA 100 MeV 5 × 5 cm(2) proton beam ...
Commercially available radiochromic films are primarily designed for clinical X-ray dosimetry. These films change color upon exposures to radiation as a result of solid-state polymerization (SSP). Built on a previous model developed for SSP upon exposures to ultraviolet (UV) radiation, a new model was developed in the present work for X-ray-induced coloration in Gafchromic EBT3 films. Monte Car...
The authors have studied the feasibility of using three new high-sensitivity radiochromic devices in measuring the doses to peripheral points outside the primary megavoltage photon beams. The three devices were GAFCHROMIC® EBT film, prototype Low Dose (LD) Film, and prototype LD Card. The authors performed point dosimetry using these three devices in water-equivalent solid phantoms at x = 3,5,8...
The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparin...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید