نتایج جستجو برای: fricke gel dosimeter
تعداد نتایج: 107206 فیلتر نتایج به سال:
In this work we use a 3D quantitative CT imaging ultrasound system to characterise polymer gel dosimeters. The system comprises of two identical 5 MHz 128 element phasedarray ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound...
Oxygen contamination of a polyacrylamide gel (PAG) dosimeter can have a significant detrimental effect upon the performance characteristics of the gel as a dosimeter. Oxygen contamination can occur during preparation, but can also arise from the diffusion of atmospheric oxygen through vessel walls. Even 'trace' amounts of oxygen present in any gaseous space (usually nitrogen filled) between the...
PURPOSE To obtain and assess the accuracy of 3D dose distributions and LET maps from a passively-scattered proton beam through the use of LET-dependent and LET-independent polymer gel formulations. METHODS Dose measurements were performed with BANG3-Pro2 (MGS Research, Inc, Madison, CT) polymer gel dosimeters. The dosimeters were mixed from kits and were poured into 14.5 cm high by 15 cm diam...
Radiation sensitive polymer gels are among the most promising three-dimensional dose verification tools developed to date. Polymer gel dosimeter known by the acronym MAGIC has been tested for evaluation of its use in boron neutron capture (BNCT) dosimetry. We irradiated a large (diameter 10 cm, length 20 cm) cylindrical gel phantom in the epithermal neutron beam of the Finnish BNCT facility at ...
Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comono...
Adjusting the dose of radiation which is received by a cancer patient during radiotherapy very important. The use dosimetric gels to calculate applied distribution three- dimensionally current research topic in radiotherapy. In this study, 16 different Fricke including gluconic acid (GA) were produced. These irradiated from 0 250 cGy with increments 50 cGy. MR intensity values and images, UV ab...
High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brac...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید