نتایج جستجو برای: dose volume histograms

تعداد نتایج: 613333  

2015
Yuji Nakaguchi Takeshi Ono Masato Maruyama Nozomu Nagasue Yoshinobu Shimohigashi Yudai Kai

In this study, we evaluated the performance of a three-dimensional (3D) dose verification system, COMPASS version 3, which has a dedicated beam models and dose calculation engine. It was possible to reconstruct the 3D dose distributions in patient anatomy based on the measured fluence using the MatriXX 2D array. The COMPASS system was compared with Monte Carlo simulation (MC), glass rod dosimet...

2017
Anthony Hoai-Nam Pham Ellen Yorke Andreas Rimner Abraham Jing-Ching Wu

PURPOSE To characterize the effect of the relative motion of esophagus and tumor on radiation doses to the esophagus in patients treated with stereotactic body radiation therapy for central lung tumors. METHODS AND MATERIALS Fifty fractions of stereotactic body radiation therapy in 10 patients with lung tumors within 2.5 cm of the esophagus were reviewed. The esophagus was delineated on each ...

2011
Xiaoqiang Li Xiaochun Wang Yupeng Li Xiaodong Zhang

We propose a planning method to design true 4-dimensional (4D) intensity-modulated radiotherapy (IMRT) plans, called the t4Dplan method, in which the planning target volume (PTV) of the individual phases of the 4D computed tomography (CT) and the conventional PTV receive non-uniform doses but the cumulative dose to the PTV of each phase, computed using deformable image registration (DIR), are u...

2012
Jean-Michel Hannoun-Levi Marie-Eve Chand-Fouche Catherine Dejean Adel Courdi

PURPOSE To evaluate a new calculation model estimating the equivalent dose at 2 Gy (EQD2) taking into account dose gradient in high dose rate interstitial brachytherapy (HDRIB). MATERIAL AND METHODS Forty dose-volume histograms (DVHs) of breast (20 pts) and prostate (20 pts) cancer dose distributions were reviewed. Physical prescribed doses (PPD) were 34 Gy (10f/5d) and 18 Gy (6f/2d) for brea...

2009
Anneyuko I. Saito Jonathan G. Li Chihray Liu Kenneth R. Olivier James F. Dempsey

The aim of this study was to investigate the relative accuracy of megavoltage photon-beam dose calculations employing either 5 bulk densities or independent voxel densities determined by calibration of the CT Houndsfield number. Full-resolution CT and bulk density treatment plans were generated for 70 lung or esophageal cancer tumors (66 cases) using a commercial treatment planning system with ...

Journal: :Asian Pacific journal of cancer prevention : APJCP 2013
Ahmed Nadeem Abbasi Asim Hafiz Nasir Ali Khurshid Ahmed Khan

BACKGROUND Radiation therapy is the mainstay of treatment for nasopharyngeal carcinoma. Importance of tumor coverage and challenges posed by its unique and critical location are well evident. Therefore we aimed to evaluate our radiation treatment plan through dose volume histograms (DVHs) to find planning target volume (PTV) dose coverage and factors affecting it. MATERIALS AND METHODS This r...

2014
Richard S. Pieters Henry Wagner Stephen Baker Karen Morano Kenneth Ulin Maria Giulia Cicchetti Maryann Bishop-Jodoin Thomas J. FitzGerald

BACKGROUND AND PURPOSE Hodgkin lymphoma (HL) treatment has evolved to reduce or avoid radiotherapy (RT) dose and volume and minimize the potential for late effects. Some older adolescents are treated on adult protocols. The purpose of this study is to examine the protocol assignment of older adolescents and its impact on radiation dose to relevant thoracic structures. MATERIALS AND METHODS Co...

2014
Jonas D. Fontenot

The purpose of this study was to assess the accuracy and efficacy of an automated treatment plan verification, or "secondary check", tool (Mobius3D), which uses a reference dataset to perform an independent three-dimensional dose verification of the treatment planning system (TPS) dose calculation and assesses plan quality by comparing dose-volume histograms to reference benchmarks. The accurac...

Journal: :Physics in medicine and biology 2005
N Reynaert M Coghe B De Smedt L Paelinck B Vanderstraeten W De Gersem B Van Duyse C De Wagter W De Neve H Thierens

Two Monte Carlo dose engines for radiotherapy treatment planning, namely a beta release of Peregrine and MCDE (Monte Carlo dose engine), were compared with Helax-TMS (collapsed cone superposition convolution) for a head and neck patient for the Elekta SLi plus linear accelerator. Deviations between the beta release of Peregrine and MCDE up to 10% were obtained in the dose volume histogram of th...

نمودار تعداد نتایج جستجو در هر سال