نتایج جستجو برای: curved strut

تعداد نتایج: 20864  

Journal: :Circulation. Cardiovascular interventions 2010
Giulio Guagliumi Vasile Sirbu Giuseppe Musumeci Hiram G Bezerra Alessandro Aprile Hiroyuki Kyono Luigi Fiocca Aleksandre Matiashvili Nikoloz Lortkipanidze Angelina Vassileva Jeffrey J Popma Dominic J Allocco Keith D Dawkins Orazio Valsecchi Marco A Costa

BACKGROUND Polymer-coated drug-eluting stents are effective in preventing restenosis but have been associated with delayed healing and incomplete strut coverage. It is unknown whether paclitaxel-eluting stents (PES) with minimal biodegradable abluminal coating enhances strut coverage while preventing neointimal hyperplasia. Using optical coherence tomography (OCT) as a primary imaging modality,...

In this study, the performance of triangular added damping and stiffness (TADAS) dampers combined with curved dampers (Curved-TADAS damper) is evaluated in moment resisting steel frame (MRSF). These dampers are passive and install in the beam-column connection region. Variable parameters of this study involve the width of curved damper (50, 75 and 100 mm), the thickness of TADAS damper (5 and 1...

Journal: :BioMedical Engineering OnLine 2008
Frank JH Gijsen Francesco Migliavacca Silvia Schievano Laura Socci Lorenza Petrini Attila Thury Jolanda J Wentzel Anton FW van der Steen Patrick WS Serruys Gabriele Dubini

BACKGROUND The process of restenosis after a stenting procedure is related to local biomechanical environment. Arterial wall stresses caused by the interaction of the stent with the vascular wall and possibly stress induced stent strut fracture are two important parameters. The knowledge of these parameters after stent deployment in a patient derived 3D reconstruction of a diseased coronary art...

Journal: :Circulation. Cardiovascular interventions 2016
Johan Bennett Maarten Vanhaverbeke Nina Vanden Driessche Tom Adriaenssens Nick Hiltrop Walter Desmet Peter Sinnaeve Christophe Dubois

BACKGROUND Although bioresorbable scaffolds offer potential advantages compared with metallic drug-eluting stents in the treatment of complex coronary bifurcation lesions, there are concerns that the polymeric scaffold integrity may be compromised. This in vivo study sought to provide insights about the feasibility of performing complex bifurcation stenting with Absorb bioresorbable vascular sc...

1999
Nikhil M. Rao Clint L. Dancey Ricardo D. Burdisso

i Reduction of Unsteady Stator – Rotor Interaction by Trailing Edge Blowing Using MEMS Based Microvalves by Nikhil M. Rao Dr. W.F. Ng, Chairman Mechanical Engineering (ABSTRACT) This research performs an experimental study of a trailing edge blowing system that can adapt to variations in flow parameters and reduce the unsteady stator-rotor interaction at all engine operating conditions. The fan...

Journal: :Annals of Biomedical Engineering 2009

Journal: :Mathematics and Mechanics of Solids 2022

Truss structures composed of members that work exclusively in tension or compression appear several problems science and engineering, e.g., the study resisting mechanisms masonry structures, as well design spider web-inspired web structures. This generalizes previous results on existence cable webs are able to support assigned sets nodal forces under tension. We extend such a problem limit anal...

Journal: :SDÜ Tıp Fakültesi Dergisi 2021

2003
Scott Thurston

In 1995, Allen Fisher published a poem entitled ‘Mummers’ Strut’ in an issue of the magazine West Coast Line,[1] accompanied by a statement of poetics. The poem is organised into twentyseven short numbered sections, mostly in couplets, ranging from two to twenty lines in length. The predominant impression is of a fragmented discourse that is hard to read as constructing a consistent speaking vo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید