نتایج جستجو برای: compact pixelated gamma camera

تعداد نتایج: 267766  

2014
F. Murtas

Micro-Pattern Gaseous Detectors (MPGD) have opened the way for the construction of detectors whose performance surpasses that of the previous generations in terms of spatial resolution, high-rate capability and increased radiation hardness. Led by the Micro-Mesh Gaseous Structure (Micromegas) and the Gas Electron Multiplier (GEM), some MPGDs are mature technologies used in a variety of experime...

Journal: :Advances in Mechanical Engineering 2017

2004
Andréa Sarmento André Maciel Netto Paulo Almeida-filho Ademir Amaral Luiz Freire

Evaluation of thyroid uptake, by administration of small activities of radioactive iodine (I or I), is a well-defined procedure. Nowadays, nuclear medicine departments are using scintillation cameras coupled to pinhole collimators to perform such studies. On the other hand, gamma probes, which are normally used in radioguided surgical procedures, can technically be used for measuring the thyroi...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2020

Journal: :World Journal of Surgical Oncology 2007
Carole Mathelin Samuel Salvador Sabrina Croce Norosoa Andriamisandratsoa Daniel Huss Jean-Louis Guyonnet

BACKGROUND Sentinel lymph node (SLN) procedure is now a widely accepted method of LN staging in selected invasive breast cancers (unifocal, size </= 2 cm, clinically N0, without previous treatment). Complete axillary clearance is no longer needed if the SLN is negative. However, the oncological safety of this procedure remains to be addressed in randomized clinical trials. One main pitfall is t...

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2014
Navid Zeraatkar Salar Sajedi Mohammad Hossein Farahani Hossein Arabi Saeed Sarkar Pardis Ghafarian Arman Rahmim Mohammad Reza Ay

The small-animal High-Resolution SPECT (HiReSPECT) is a dedicated dual-head gamma camera recently designed and developed in our laboratory for imaging of murine models. Each detector is composed of an array of 1.2 × 1.2 mm(2) (pitch) pixelated CsI(Na) crystals. Two position-sensitive photomultiplier tubes (H8500) are coupled to each head's crystal. In this paper, we report on a resolution-recov...

Journal: :Journal of Astronomical Instrumentation 2021

IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of [Formula: see text] pixels CdTe or CdZnTe pixelated detectors to build low power micro-gamma camera. has been designed in standard AMS CMOS 0.35[Formula: text][Formula: text]m process technology. Its consumption 800[Formula: text]W per channel. The energy range ASIC can be extended 1.1[Formul...

Journal: :IJPRAI 2002
Antonio López Rafael Molina Javier Mateos Aggelos K. Katsaggelos

SPECT images are observation data acquired by a gamma-camera following an orbit around the patient’s body, at regularly spaced angles. A reconstructed image is the discrete representation of a slice or cross-section of the isotope distribution within the patient, transversal to the gamma-camera rotation axis. Bayesian reconstruction methods have been extensively used to reconstruct medical imag...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید