نتایج جستجو برای: chromic dosimeter presage

تعداد نتایج: 3817  

2008
G. SARRABAYROUSE S. SISKOS

-The influence of the irradiation dose on the parameters which control the temperature sensitivity of thick oxide p-MOS ionising radiation dosimeters is investigated. The temperature sensitivity of the threshold voltage, the carrier mobility and the minimum temperature coefficient current appear to be dose-dependent contrary to what is generally considered. The consequences on the dose measurem...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2012
Matthew T Studenski Ying Xiao Amy S Harrison

Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose whil...

2003
M. J. Pardus

To eliminate hazardous hexavalent chromium from a brass wire-mill waste, hydrogen peroxide was examined In place of chromic acid for pickling, first in bench-scale tests and then in plant tests. Nthough the elimination of chromic acid requires more rigid control of the ~ wastewater treatment operation and increases the zinc content of the waste-treatment effluent, the economic benefit of substi...

2008
Ridthee Meesat Jean-Paul Jay-Gerin Abdelouahed Khalil Martin Lepage

In this study, our aim is to assess the potential of Fricke and polyacrylamide gel (PAG) dosimeters to quantitatively evaluate the efficiency of potential radiation sensitizers/protectors and antioxidants. These compounds are of importance in radiotherapy as well as in disease prevention and promotion of health. The basic principle of the Fricke dosimeter is the radiation-induced oxidation of F...

Journal: :Annals of Otology, Rhinology & Laryngology 1897

2014
Wook Jae Yoo Sang Hun Shin Dayeong Jeon Seunghan Hong Hyeok In Sim Seon Geun Kim Kyoung Won Jang Seunghyun Cho Won Sik Youn Bongsoo Lee

A miniature fiber-optic dosimeter (FOD) system was fabricated using a plastic scintillating fiber, a plastic optical fiber, and a multi-pixel photon counter to measure real-time entrance surface dose (ESD) during radiation diagnosis. Under varying exposure parameters of a digital radiography (DR) system, we measured the scintillating light related to the ESD using the sensing probe of the FOD, ...

Journal: :Journal of photochemistry and photobiology. B, Biology 2009
P W Schouten A V Parisi D J Turnbull

Previous research has proven that the Poly (2,6-dimethyl-1, 4-phenylene oxide) (PPO) dosimeter is capable of receiving both in-air and underwater UV exposures that are significantly greater than those of the more commonly used polysulphone dosimeter, within a range of accuracy close to what would be expected of dosimetric measurements made in-air provided that the necessary calibrations are com...

2017
Yoichi Watanabe Leighton Warmington N Gopishankar

Accurate dose measurement tools are needed to evaluate the radiation dose delivered to patients by using modern and sophisticated radiation therapy techniques. However, the adequate tools which enable us to directly measure the dose distributions in three-dimensional (3D) space are not commonly available. One such 3D dose measurement device is the polymer-based dosimeter, which changes the mate...

2009
M. F. Desrosiers M. Peters J. M. Puhl

The response of high-dose-range chemical dosimeters is dependent on the dosimeter temperature during irradiation. Typically, irradiation temperatures are estimated by measurements, calculations, or some combination of the two. Then using the temperature coefficient for the dosimetry system, the dosimeter response is adjusted or corrected to be consistent with the irradiation temperature for the...

Journal: :Journal of occupational and environmental hygiene 2008
David C Byrne Efrem R Reeves

This study was conducted as part of a project involving the evaluation of a new type of noise exposure monitoring paradigm. Laboratory tests were conducted to assess how "nonstandard" dosimeter microphones and microphone positions measured noise levels under different acoustical conditions (i.e., diffuse field and direct field). The data presented in this article reflect measurement differences...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید