نتایج جستجو برای: aphakic eye

تعداد نتایج: 156983  

حسن پور, مهدی , نوروزی , حمید , ولائی , ناصر ,

Background and purpose : Many aphahic patients have unfavorable vision either with glasses or contact lens. In this study Visual outcome of Seconary (I.O.L) was implantation in aphakic patients referred to Imam Hossein Haspital 1994 evaluated. Materials and Methods : In a clinical trial with sequential sampling , 30 aphakic patients (26 males , 4 females mean of age 24.4 ± 10.8 years) who...

Journal: :Open Journal of Ophthalmology 2021

Introduction: Iris-claw Intraocular Lens (IOL) is one of the alternatives to correct aphakia without sufficient capsular support. This technique preferred because it has a simple procedure. IOL was originally designed be fixated on anterior chamber. The use retropupillary fixation increasing location more physiologic and shows less risk corneal endothelial damage. Purpose: To describe safety ef...

Journal: :The British journal of ophthalmology 1989
M V Gibbens R Goel S E Smith

Pupil diameters in the dark, in the light, and after mydriasis with tropicamide+ phenylephrine have been measured in 25 patients before and six months after cataract surgery. The aphakic pupil showed reduced mobility as evidenced by a smaller diameter in the and a larger one in the light. In patients who had intracapsular extraction or extracapsular extraction with intraocular lens implantation...

Journal: :Journal of clinical and diagnostic research : JCDR 2005
Laxman Dasar Chaitra Pujar Kanwarpal Singh Gill Madhuri Patil Mallikarjun Salagar

AIM To study the indications of penetrating keratoplasty in Southern India. SETTINGS AND DESIGN Retrospective study. MATERIAL AND METHODS Retrospective evaluation of eye bank records from December, 2002 to December, 2012 with respect to indications for penetrating keratoplasty. RESULTS During the period considered for study, 102 penetrating keratoplasties were performed. The leading indic...

Journal: :Collegium antropologicum 2008
Bozidar Vojniković Miran Coklo Alan Bosnar

After testing all types of implanted IOLs with spectrophotometer, author estimated that filtering of sun light is not successful, leaving open the possibility of development of AMD after cataract surgery. This is especially serious problem in implantation of IOLs to children. Until recently, implantation of intraocular lenses without or with inappropriate UV protection was not considered a seri...

2012
Virgilio Galvis Alejandro Tello Giuseppe Miotto Carlos M. Rangel

A 44-year-old man with anterior megalophthalmos arrived at the clinic presenting a cataract in the right eye. The corneal diameter was 13 mm. Iridodonesis and phacodonesis were evident during slit lamp examination. Anterior chamber depth was 5.89 mm, and the diameter of the capsular bag was approximately 14.45 mm. Due to the large capsular bag, a standard posterior chamber intraocular lens was ...

Journal: :The British journal of ophthalmology 1988
K U Loeffler J L Jay

The tissue reaction to a functioning Molteno implant has been studied by light microscopy and by scanning and transmission electron microscopy. The material was obtained from an aphakic 83-year-old human eye which required enucleation because of intractable bullous keratopathy, despite well controlled intraocular pressure. The tissue response around the silicone rubber tube was that of simple f...

Journal: :British Journal of Ophthalmology 1973

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید