نتایج جستجو برای: anthropomorphic phantom

تعداد نتایج: 19149  

Journal: :international journal of advanced biological and biomedical research 2015
hadi taleshi ahangari ali ghanbari nasroallah moradi kor

objective: different categories are available for estimating of radiation dose. radioisotopes with the same energy and almost the same physical properties have similar effects. monte carlo technique is a computerized method based on mathematical simulation of physical processes. the main purpose of this study is to show that beta particles are not able to penetrate deep into the water. also dif...

2016
Ryan G Lafratta

Gamma index pass rates were evaluated for an anthropomorphic phantom using both 2D and 3D calculations. The phantom was irradiated with the traditional dosimetry insert loaded with radiochromic film and TLD, and then with a 3D dosimetry insert. A comparison with the calculated dose distribution showed that both the PRESAGE® dosimeter and the film and TLD system agreed with the plan to within 5%...

Journal: :Radiation protection dosimetry 2016
Bharti Kataria Michael Sandborg Jonas Nilsson Althén

Automatic exposure control (AEC) in computed tomography (CT) facilitates optimisation of dose absorbed by the patient. The use of AEC requires appropriate 'patient centring' within the gantry, since positioning the patient off-centre may affect both image quality and absorbed dose. The aim of this experimental study was to measure the variation in organ and abdominal surface dose during CT exam...

2015
Yongjin Sung W. Paul Segars Adam Pan Masami Ando Colin J. R. Sheppard Rajiv Gupta

X-ray phase-contrast imaging (XPCI) can dramatically improve soft tissue contrast in X-ray medical imaging. Despite worldwide efforts to develop novel XPCI systems, a numerical framework to rigorously predict the performance of a clinical XPCI system at a human scale is not yet available. We have developed such a tool by combining a numerical anthropomorphic phantom defined with non-uniform rat...

Journal: :Applied sciences 2021

The aim of this study was to develop and apply an evaluation method for assessing the accuracy a novel 3D EPID back-projection algorithm in vivo dosimetry. Dosimetry Check (DC) 5.8 evaluated. A slab phantom homogeneously filled, or with air bone inserts, used fluence reconstruction different squared fields. VMAT plans anatomical sites were delivered on anthropomorphic phantom. Dose distribution...

Journal: :Nuclear Technology & Radiation Protection 2022

Advances of radiation delivery devices have increased the complexity oncology treatments. Herewith, outcome treatment, as well patient safety, strongly depend on consistency absorbed dose delivery. Both can be ensured by comprehensive system verification calculated distributions. Standard method is evaluation distribution according to gamma method, using a 2-D detector and homogeneous phantom, ...

2014
Mark Fisher Christopher Applegate Mohammad Ryalat Stephen Laycock Mark Hulse Daniel Emmens Duncan Bell

This paper presents the preclinical evaluation of a novel immobilization system for patients undergoing external beam radiation treatment of head and neck tumors. An immobilization mask is manufactured directly from a 3-D model, built using the CT data routinely acquired for treatment planning so there is no need to take plaster of Paris moulds. Research suggests that many patients find the mou...

2010
Marios A. Gavrielides Lisa M. Kinnard Kyle J. Myers Jennifer Peregoy William F. Pritchard Rongping Zeng Juan Esparza John Karanian Nicholas Petrick

A number of interrelated factors can affect the precision and accuracy of lung nodule size estimation. To quantify the effect of these factors, we have been conducting phantom CT studies using an anthropomorphic thoracic phantom containing a vasculature insert to which synthetic nodules were inserted or attached. Ten repeat scans were acquired on different multi-detector scanners, using several...

Farshad Ghasemi Ferydoon Abbasi Davani Hamid Emami Mitra Ansari Mohhamad Lamehi Rashti Shahram Monadi

Introduction: Total skin electron irradiation technique is used in treatment of the mycosis fungoid. The implementation of this technique requires non-standard measurements and complex dosimetry methods. Operating procedures for total skin electron irradiation and its dosimetry vary in different radiation therapy centers in the world. In this article, validation of TSET techniq...

H. Gharaati, H.R. Baghani, S.M. Hosseini Daghigh, S.M.R. Aghamiri, S.R. Mahdavi,

Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید