نتایج جستجو برای: and sinogram

تعداد نتایج: 16827239  

2008

ID: 8177 Title: A Clinical Example of the Helical Tomotherapy Thread Effect: Robustness Discussion Purpose: A previous study explained why pitches of 0.86/n, where n is an integer, will provide the best junctioning of a helically delivered and diverging beam. The previous treatment was theoretical and based on unmodulated examples. In this study, a clinically relevant case of a palliative lung ...

2016
Jae Kyu Choi Bin Dong Xiaoqun Zhang X. Zhang

X-ray computed tomography (CT) is one of widely used diagnostic tools for medical and dental tomographic imaging of the human body. However, the standard filtered backprojection reconstruction method requires the complete knowledge of the projection data. In the case of limited data, the inverse problem of CT becomes more ill-posed, which makes the reconstructed image deteriorated by the artifa...

2005
Hongbing Lu Guoping Han Dongqing Chen Lihong Li Zhengrong Liang

In dynamic SPECT studies, the acquired sinograms have both spatial and temporal correlations among the time sequence, in addition to the spatial correlation within each time frame (i.e., a three-dimensional (3D) sinogram). In this paper, we propose a theoretically based multi-frame filtering algorithm, which considers both the spatial and temporal correlations, for restoring the gated sinograms...

2008
Jing Wang Hongbing Lu Zhengrong Liang Daria Eremina Guangxiang Zhang Su Wang John Chen James Manzione

Computed tomography (CT) has been well established as a diagnostic tool through hardware optimization and sophisticated data calibration. For screening purposes, the associated X-ray exposure risk must be minimized. An effective way to minimize the risk is to deliver fewer X-rays to the subject or lower the mAs parameter in data acquisition. This will increase the data noise. This work aims to ...

Journal: :Journal of synchrotron radiation 2015
Pierre Paleo Alessandro Mirone

Ring artifacts are a very common problem in tomographic reconstruction, and numerous methods exist to either pre-process the sinogram or correct the reconstructed slice. A novel approach to perform the correction as part of the reconstruction process is presented. It is shown that for iterative techniques, which amount to optimizing an objective function, the ring artifacts correction can be ea...

2001
M. Leahy

We describe methods for computing mean and variance approximations to instantaneous and average rate estimates obtained from continuous-time penalized ML dynamic PET image reconstructions. The derivation is based on writing the likelihood for the list-mode data as the limiting case of the likelihood for binned sinogram data as the temporal bin width goes to zero. We show that approximations of ...

Journal: :Medical physics 2005
Wei Lu Parag J Parikh James P Hubenschmidt David G Politte Bruce R Whiting Jeffrey D Bradley Sasa Mutic Daniel A Low

Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, develope...

Journal: :Journal of computer assisted tomography 2016
Stephan Baumueller Regina Hilty Thi Dan Linh Nguyen Walter Weder Hatem Alkadhi Thomas Frauenfelder

OBJECTIVE The purpose of this study was to evaluate the influence of sinogram-affirmed iterative reconstruction (SAFIRE) on quantification of lung volume and pulmonary emphysema in low-dose chest computed tomography compared with filtered back projection (FBP). METHODS Enhanced or nonenhanced low-dose chest computed tomography was performed in 20 patients with chronic obstructive pulmonary di...

2016
Min Yang Wen Zhang Xiaojun Wu Dongtao Wei Yixin Zhao Gang Zhao Xu Han Shunli Zhang

For the analysis of interior geometry and property changes of a large-sized analog model during a loading or other medium (water or oil) injection process with a non-destructive way, a consecutive X-ray computed tomography (XCT) short-scan method is developed to realize an in-situ tomography imaging. With this method, the X-ray tube and detector rotate 270° around the center of the guide rail s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید