نتایج جستجو برای: aliii selective electrode
تعداد نتایج: 259980 فیلتر نتایج به سال:
The work described here comprises the determination of Fe(III) by ion selective potentiometry using a coated-wire ion-selective electrode (CWISE) based on iron–cyclam complex. Linear Nernstian response for this electrode was obtained over the total Fe(III) concentration range of 1× 10−2 to 1× 10−6 M in 0.05 M HNO3, H2SO4, HClO4, HCl, KNO3 and KCl media, with a slope of 60± 5 mV per decade chang...
Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...
In the present paper, electrochemical methods were used to investigate the behavior of ascorbic acid at a carbon paste electrode modified with 2,2'-((1E)-(1,2 phenylenebis(azanylylidene)) bis(methanylylidene))bis(benzene-1,4-diol) (PBD) and oxidized multiwall carbon nanotubes. The modified carbon paste electrode showed high electrocatalytic activity toward ascorbic acid; the current was enhance...
Preparation and performance of a cost effective silver sulfide based bromide selective membrane is described. A solid contact between membrane and body of the electrode was examined as an ion-selective electrode by determining S 2and Br ions by direct potentiometry. A linear response to bromide ion from 2 x 10 -5 to 10 -1 M with a slope of 57.3 mV per decade [Br ] is observed. The membrane has ...
The preparation conditions and the performance of a small size Ag/Ag2S selective electrode are described. The analytical behaviour of this electrode, made by chemical treatment of a silver wire, is described in terms of potential concentration curves, standard potential, lifetime and electrode selectivity. A series of electrodes have been prepared and investigated. Their response and selectivit...
In this work the ion-selective response of an electrolyte-gated carbon-nanotube field-effect transistor (CNT-FET) towards K(+), Ca(2+) and Cl(-) in the biologically relevant concentration range from 10(-1) M to 10(-6) M is demonstrated. The ion-selective response is achieved by modifying the gate-electrode of an electrolyte-gated CNT-FET with ion-selective membranes, which are selective towards...
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید