نتایج جستجو برای: accelerometer

تعداد نتایج: 7304  

Journal: :Journal of physical activity & health 2013
John Ronald Sirard Peter Hannan Gretchen J Cutler Dianne Nuemark-Sztainer

BACKGROUND The purpose of this paper is to evaluate self-reported physical activity of young adults using 1-week and 1-year recall measures with an accelerometer as the criterion measure. METHODS Participants were a subsample (N = 121, 24 ± 1.7 yrs) from a large longitudinal cohort study. Participants completed a detailed 1-year physical activity recall, wore an accelerometer for 1 week and t...

Journal: :Journal of physical activity & health 2012
Lydia Kwak Maria Hagströmer Michael Sjostrom

BACKGROUND To be able to draw any conclusions regarding the health effects of occupational physical activity (OPA), more information is needed regarding valid measures to assess OPA. Aims were to compare OPA as assessed with the International Physical Activity Questionnaire long version (IPAQ-L) with OPA assessed with an accelerometer and to assess the contribution of OPA to total PA. METHODS...

Journal: :Journal of physical activity & health 2008
Kathleen Y Wolin Daniel P Heil Sandy Askew Charles E Matthews Gary G Bennett

BACKGROUND The International Physical Activity Questionnaire-Short Form (IPAQ-S) has been evaluated against accelerometer-determined physical activity measures in small homogenous samples of adults in the United States. There is limited information about the validity of the IPAQ-S in diverse US samples. METHODS 142 Blacks residing in low-income housing completed the IPAQ-S and wore an acceler...

2017
Triin Rääsk Jarek Mäestu Evelin Lätt Jaak Jürimäe Toivo Jürimäe Uku Vainik Kenn Konstabel

Self-report measures of physical activity (PA) are easy to use and popular but their reliability is often questioned. Therefore, the general aim of the present study was to investigate the association of PA questionnaires with accelerometer derived PA, in a sample of adolescent boys. In total, 191 pubertal boys (mean age 14.0 years) completed three self-report questionnaires and wore an acceler...

Journal: :Journal of sport rehabilitation 2015
Elizabeth Lawinger Tim L Uhl Mark Abel Srinath Kamineni

OBJECTIVE The overarching goal of this study was to examine the use of triaxial accelerometers in measuring upper-extremity motions to monitor upper-extremity-exercise compliance. There were multiple questions investigated, but the primary objective was to investigate the correlation between visually observed arm motions and triaxial accelerometer activity counts to establish fundamental activi...

Journal: :Optics letters 2011
G Y Chen X L Zhang G Brambilla T P Newson

The proof-of-concept demonstration of a microfiber-based flexural disc accelerometer is presented. The reduced microfiber size and bending radii give rise to high device compactness and responsivity. A flexural disc accelerometer manufactured from a 10 mm long microfiber showed a performance of ~2.2 rad/g, with the responsivity expected to increase proportionally with the microfiber length.

2010
Natasha Alves Ervin Sejdić Bhupinder Sahota Tom Chau

BACKGROUND Recently, pattern recognition methods have been deployed in the classification of multiple activation states from mechanomyogram (MMG) signals for the purpose of controlling switching interfaces. Given the propagative properties of MMG signals, it has been suggested that MMG classification should be robust to changes in sensor placement. Nonetheless, this purported robustness remains...

Journal: :Medicine and science in sports and exercise 2004
Margarita S Treuth Kathryn Schmitz Diane J Catellier Robert G McMurray David M Murray M Joao Almeida Scott Going James E Norman Russell Pate

PURPOSE To derive a regression equation that estimates metabolic equivalent (MET) from accelerometer counts, and to define thresholds of accelerometer counts that can be used to delineate sedentary, light, moderate, and vigorous activity in adolescent girls. METHODS Seventy-four healthy 8th grade girls, age 13 - 14 yr, were recruited from urban areas of Baltimore, MD, Minneapolis/St. Paul, MN...

2010
Shigeru Inoue Yumiko Ohya Yuko Odagiri Tomoko Takamiya Masamitsu Kamada Shinpei Okada Catrine Tudor-Locke Teruichi Shimomitsu

BACKGROUND Differences in the characteristics of respondents and nonrespondents to a survey can be a cause of selection bias. The aim of this study was to determine the sociodemographic and lifestyle characteristics of respondents to a field-based accelerometry survey. METHODS A cross-sectional mail survey was sent to 4000 adults (50% male; age 20 to 69 years) who were randomly selected from ...

Journal: :Journal of sports science & medicine 2015
Martin Buchheit Andrew Gray Jean-Benoit Morin

The aim of the present study was to examine the ability of a GPS-imbedded accelerometer to assess stride variables and vertical stiffness (K), which are directly related to neuromuscular fatigue during field-based high-intensity runs. The ability to detect stride imbalances was also examined. A team sport player performed a series of 30-s runs on an instrumented treadmill (6 runs at 10, 17 and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید