نتایج جستجو برای: absorbance

تعداد نتایج: 9354  

Journal: :BioTechniques 2000
R T Liermann J D Dinman L A Sylvers J C Jackson

plying by its reciprocal). To use that value for microplate samples, absorbance values must be normalized to a 1 cm path length. This can be done by determining a conversion factor for a given sample volume and microplate. Alternatively, several microplate spectrophotometers use infrared absorbance measurements to determine path length on a well-by-well basis, and absorbance values can be norma...

Journal: :Water research 2009
Ren Zhuo Chen Stephen A Craik James R Bolton

The action spectra of Bacillus subtilis spores (ATCC6633) and Salmonella typhimurium LT2 were characterized using physical radiometry for irradiance measurements and a multiple target model to interpret the inactivation kinetics. The observed action spectrum of B. subtilis spores deviated significantly from the relative absorbance spectrum of the DNA purified from the spores, but matched quite ...

2010
Mingqiang Zou Fuqiang yang Jixiang Ma Yan Chen Lin Cao Feng Liu

Nanoscale titanium dioxide is an important physical sun-block material and is widely used in sunscreen. In our test, the influences of the particle size and crystal structure on light absorbance were examined. The experiment shows that the absorbance (Abs) of nanoscale titanium dioxide in UV-ray district is much higher than it in visible light district under the same concentration (0.04 g/L). T...

Journal: :BioTechniques 2018
Hua-Jun He Erica V Stein Paul DeRose Kenneth D Cole

We compared different methods (absorbance, fluorescent dye-binding, and digital PCR) for measuring the concentrations of human genomic DNA from cultured cells and absorbance measurements of a synthetic DNA oligonucleotide. NIST Standard Reference Material (SRM) 2082, a pathlength absorbance standard, was used to benchmark the absorbance measurements done with microvolume spectrophotometers and ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2015
Yuhei Yamamoto Toshihiro Shirasaki Akira Yonetani Shoji Imai

The measurement conditions for determining boron using graphite furnace-atomic absorption spectrometry (GF-AAS) were investigated. Differences in the boron absorbance profiles were found using three different commercially available GF-AAS instruments when the graphite atomizers in them were not tuned. The boron absorbances found with and without adjusting the graphite atomizers suggested that a...

2006
Hadas Mamane

Ultraviolet UV absorbance measurements are subject to significant error using a standard spectrophotometer when particles or aggregates that scatter light are present. True UV absorbance for highly turbid waters should be measured using integrating sphere IS spectrophotometry that allows the collection of reflected and transmitted radiation simultaneously. This is especially important when the ...

Journal: :Plant physiology 1970
B T Storey

Redox changes of the flavoproteins of mung bean (Phaseolus aureus) mitochondria were measured by differential absorbance at 468 to 493 nanometers and by fluorescence emission above 500 nanometers excited at 436 nanometers. Four flavoproteins are distinguishable by the ratio of their fluorescence to absorbance changes, and by their requirement, or lack of it, for energy-linked reverse electron t...

Journal: :Vision Research 1997
J. K. Bowmaker L. A. Heath S. E. Wilkie D. M. Hunt

Microspectrophotometric examination of the retinal photoreceptors of the budgerigar (shell parakeet), Melopsittacus undulatus (Psittaciformes) and the zebra finch, Taeniopygia guttata (Passeriformes), demonstrate the presence of four, spectrally distinct classes of single cone that contain visual pigments absorbing maximally at about 565, 507, 430-445 and 360-380 nm. The three longer-wave cone ...

Journal: :Plant physiology 1979
G Horváth H A Niemi M Droppa A Faludi-Dániel

In intact (type A) chloroplasts isolated from mesophyll protoplasts of maize (Zea mays L. convar. KSC 360) the flash-induced 515 nanometer absorbance change was much higher than in conventionally prepared (types B and C) chloroplasts. The 515 nanometer signal of type A chloroplasts exhibited a biphasic rise: the initial very fast rise (rise time <<1 millisecond) was followed by a slow increase ...

2006
I. Bogrekci W. S. Lee

This study was conducted to investigate the effects of soil moisture content on the absorbance spectra of sandy soils with different phosphorus (P) concentrations using ultraviolet (UV), visible (VIS), and near-infrared (NIR) absorbance spectroscopy. Sieve sizes were 125, 250, and 600 m for fine, medium, and coarse, respectively. The medium size of the samples was used for the study. Investigat...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید