نتایج جستجو برای: 4v

تعداد نتایج: 3301  

Journal: :American journal of physiology. Gastrointestinal and liver physiology 2012
Ze-Feng Xia Danielle M Fritze Ji-Yao Li Biaoxin Chai Chao Zhang Weizhen Zhang Michael W Mulholland

Nesfatin-1, a novel hypothalamic peptide, inhibits nocturnal feeding behavior and gastrointestinal motility in rodents. The effects of nesfatin-1 on gastrointestinal secretory function, including gastric acid production, have not been evaluated. Nesfatin-1 was injected into the fourth intracerebral ventricle (4V) of chronically cannulated rats to identify a nesfatin dose sufficient to inhibit f...

2014
Peng-cheng Liu Yun-ji Yang Run Liu He-xi Shu Jin-peng Gong Yong Yang Qi Sun Xing Wu Ming Cai

PURPOSE The electron beam melting (EBM) Ti-6Al-4V material technology has been developed over a short time period. It was introduced through a research to develop Ti-6Al-4V implants for patients, but EBM printed locking compression plates have not been used for clinical implants. The main purpose of this study is to find whether the EBM Ti-6Al-4V plate suit for clinical implants. METHODS Firs...

Journal: :Dalton transactions 2012
Michinori Sumimoto Teruyuki Honda Yukio Kawashima Kenji Hori Hitoshi Fujimoto

The molecular geometries, electronic structures, and excitation energies of tin and lead phthalocyanine compounds, SnPc, PbPc, Sn(Pc)(2), and Pb(Pc)(2), were investigated using the B3LYP method within a framework of density functional theory (DFT). The geometries of SnPc, PbPc, Sn(Pc)(2), and Pb(Pc)(2) were optimized under C(4v), C(4v), D(4d), and D(4d) molecular symmetries, respectively. The e...

2015
Eric Wycisk Shafaqat Siddique Dirk Herzog Frank Walther Claus Emmelmann

Additive manufacturing technologies are in the process of establishing themselves as an alternative production technology to conventional manufacturing, such as casting or milling. Especially laser additive manufacturing (LAM) enables the production of metallic parts with mechanical properties comparable to conventionally manufactured components. Due to the high geometrical freedom in LAM, the ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تربیت مدرس 1387

فرایند ماشینکاری کاربرد گسترده ای در تولید قطعات صنعتی دارد. تحقیقات زیادی برای بهینه سازی فرایندهای مختلف ماشینکاری در چند دهه اخیر انجام شده است. در میان راهکارهای مختلف مدل سازی فرایند، شبیه سازی کامپیوتری به روش المان محدود (fem) به دلیل توانائی در ارائه توزیع نیرو، تنش، کرنش، نرخ کرنش و دما و ... از ارزش و اهمیتی زیادی برخوردار بوده است. دقت و قابلیت اطمینان نتایج شبیه سازی، شدیدا وابسته ب...

2007
Masafumi Morita Tokiko Hashimoto Kiyoshi Yamauchi Yuji Suto Takayuki Homma Yuji Kimura

This study was conducted to evaluate the biocompatibility of titanium-nickel shape memory alloy used as a medical implant material. The authors carried out the following electrochemical corrosion test and in vivo and in vitro biological tests for the alloy and some metal and alloys clinically used previously to compare the intensities concerned with the biological reactions, that is, (1) anodic...

2018
Alethea Liens Aurélien Etiemble Pascaline Rivory Sandra Balvay Jean-Marc Pelletier Sandrine Cardinal Damien Fabrègue Hidemi Kato Philippe Steyer Tais Munhoz Jerome Adrien Nicolas Courtois Daniel J Hartmann Jérôme Chevalier

Ti40Zr10Cu36Pd14 Bulk Metallic Glass (BMG) appears very attractive for future biomedical applications thanks to its high glass forming ability, the absence of toxic elements such as Ni, Al or Be and its good mechanical properties. For the first time, a complete and exhaustive characterization of a unique batch of this glassy alloy was performed, together with ISO standard mechanical tests on ma...

2012
Yoshimitsu Okazaki

Zr, Nb, and Ta as alloying elements for Ti alloys are important for attaining superior corrosion resistance and biocompatibility in the long term. However, note that the addition of excess Nb and Ta to Ti alloys leads to higher manufacturing cost. To develop low-cost manufacturing processes, the effects of hot-forging and continuous-hot-rolling conditions on the microstructure, mechanical prope...

2006
T. A. VENKATESH B. P. CONNER C. S. LEE A. E. GIANNAKOPOULOS T. C. LINDLEY S. SURESH

A systematic investigation of the fretting fatigue behavior of the titanium alloy Ti-6Al-4V in both the mill-annealed (MA) and the solution-treated and overaged (STOA) conditions was carried out. A sphere-on-flat fretting fatigue device was used that facilitated real-time control and monitoring of all the relevant parameters such as the contact geometry, contact (normal and tangential) loads, a...

Journal: :Annals of the Rheumatic Diseases 2021

Background: In rheumatoid arthritis (RA), autoantibodies namely anticitrullinated protein antibodies (Anti-CCP) have prognostic value, independently predicting radiologic progression. However, the evidence is still controversial about how autoantibody levels change over time and their role in treatments outcomes monitoring disease activity RA. Objectives: This study aimed to characterize change...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید