نتایج جستجو برای: توبولار اکسترنال فیکساتور ao

تعداد نتایج: 58650  

2006
L. A. Poyneer D. W. Palmer K. N. LaFortune B. Bauman Lisa A. Poyneer David W. Palmer Kai N. LaFortune Brian Bauman

Correlation wave-front sensing can improve Adaptive Optics (AO) system performance in two keys areas. For point-source-based AO systems, Correlation is more accurate, more robust to changing conditions and provides lower noise than a centroiding algorithm. Experimental results from the Lick AO system and the SSHCL laser AO system confirm this. For remote imaging, Correlation enables the use of ...

Journal: :Annual review of vision science 2000
Austin Roorda Jacque L Duncan

This review starts with a brief history and description of adaptive optics (AO) technology, followed by a showcase of the latest capabilities of AO systems for imaging the human retina and an extensive review of the literature on where AO is being used clinically. The review concludes with a discussion on future directions and guidance on usage and interpretation of images from AO systems for t...

Journal: :Chemical communications 2011
Yan Shi Wei Tao Huang Hong Qun Luo Nian Bing Li

G-quadruplex structure aptamer (PS2.M) can capture acridine orange (AO) from reduced graphene oxide (rGO). When the AO-PS2.M/rGO mixture is incubated with hemin, the specific binding of hemin with PS2.M results in a release of AO from PS2.M and return of AO back to rGO. Based on the quenching of fluorescence, the target hemin was detected sensitively and selectively, giving a detection limit of...

2004
J. H. C. Gash C. Huntingford J. A. Marengo R. A. Betts P. M. Cox R. Fu A. W. Gandu P. P. Harris L. A. T. Machado C. von Randow M. A. Silva Dias

1 Centre for Ecology and Hydrology, Wallingford, UK 2 Centro de Previs~ao de Tempo e Estudos Climaticos, Cachoeira Paulista, SP, Brazil 3 Hadley Centre for Climate Prediction and Research, Met Office, Exeter, UK 4 Centro T ecnico Aeroespacial, S~ao Jos e dos Campos, SP, Brazil 5 Georgia Institute of Technology, Atlanta, GA, USA 6 University of S~ao Paulo, S~ao Paulo, SP, Brazil 7 Alterra, Wagen...

Journal: :FEBS letters 1995
M E Evers W Harder M Veenhuis

We have studied the in vitro inactivation/dissociation and subsequent reactivation/re-assembly of peroxisomal alcohol oxidases (AO) from the yeasts Hansenula polymorpha and Pichia pastoris. Both proteins are homo-oligomers consisting of eight identical subunits, each containing one FAD as the prosthetic group. They were both rapidly inactivated upon incubation in 80% glycerol, due to their diss...

2014
Jisoo Hong Myung K. Kim

Adaptive optics (AO) in astronomical imaging is a technique to improve the quality of image by compensating aberrations induced by atmospheric turbulence. Digital holographic AO (DHAO) is one attractive option to implement AO scheme because it is capable of directly measuring the phase profile of aberration without complicated calculation or loss of resolution of CCD. Hence, if applicable, DHAO...

2012
C. Baranec R. Riddle A. N. Ramaprakash N. Law S. Tendulkar S. Kulkarni R. Dekany K. Bui J. Davis M. Burse H. Das S. Hildebrandt S. Punnadi R. Smith

We have created a new autonomous laser-guide-star adaptive-optics (AO) instrument on the 60-inch (1.5-m) telescope at Palomar Observatory called Robo-AO. The instrument enables diffraction-limited resolution observing in the visible and near-infrared with the ability to observe well over one-hundred targets per night due to its fully robotic operation. RoboAO is being used for AO surveys of tar...

Journal: :Circulation 1976
A B Lewis M Takahashi

Echocardiograms were performed in 20 infants and children with isolated ventricular septal defects (VSD) undergoing cardiac catheterization. The magnitude of the left-to-right shunt was expressed as the pulmonary-to-systemic flow ratio (Qp/Os) and was compared to a ratio of the echographic left atrial (LA) diameter to the aortic root (Ao) diameter (LA/Ao). The Qp/Qs was also compared to LA/m2. ...

Journal: :The Journal of bone and joint surgery. British volume 1996
H J Kreder D P Hanel M McKee J Jupiter G McGillivary M F Swiontkowski

We sought to quantify agreement by different assessors of the AO classification for distal fractures of the radius. Thirty radiographs of acute distal radial fractures were evaluated by 36 assessors of varying clinical experience. Our findings suggest that AO 'type' and the presence or absence of articular displacement are measured with high consistency when classification of distal radial frac...

2011
Yaopeng Zhou Thomas Bifano Charles Lin Scot S. Olivier Thomas G. Bifano Joel A. Kubby

Two-photon fluorescence microscopy provides a powerful tool for deep tissue imaging. However, optical aberrations from illumination beam path limit imaging depth and resolution. Adaptive Optics (AO) is found to be useful to compensate for optical aberrations and improve image resolution and contrast from two-photon excitation. We have developed an AO system relying on a MEMS Deformable Mirror (...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید