نتایج جستجو برای: ventilation tube
تعداد نتایج: 141661 فیلتر نتایج به سال:
The effectiveness and safety of the Carden tube-oxygen injector system for ventilation was studied in 18 high-risk patients with obstructive airways disease during microlaryngeal surgery. Blood gas studies during operation demonstrated a mean Pao2 of 65.6 kPa (493 torr) and a mean PaCO2 of 4.5 kPa (34 torr) during mechanical ventilation. No serious complications were noted during operation. Fif...
I tracheobronchial injuries are fatal complications requiring immediate diagnosis and treatment. Unintentional one sided intubation, endotracheal tube cuff over-inflation, direct trauma with guides or boogie’s, double-lumen tube employment, tube replacement without cuff deflation and coughing against closed or blocked ventilation circuits are the possible causes.1, 2 Emergency or difficult intu...
Background: This study investigated the feasibility of video-assisted thoracic surgery (VATS) performed under two-lung ventilation (TLV) and single-lumen endotracheal tube (SLET) intubation in patients with spontaneous pneumothorax.
INTRODUCTION I-gel is a relatively new supra-glotitc airway device which is claimed to be superior to laryngeal mask airway. It can be used ingeneral anesthesia with spontaneous ventilation as well as with positive pressure ventilation.This study was designed to assess whether I-gel creates adequate laryngeal seal during positive pressure ventilation in patients undergoing laparoscopic surgery....
The I-gel™ is a single-use supraglottic airway device introduced in 2007 which features a non-inflatable cuff and allows passage of a tracheal tube owing to its large diameter and short length of the airway tube. In this case, the authors experienced a difficult airway management on a 4-year-old boy with underlying Goldenhar syndrome who underwent a tonsillectomy. Intubation using a laryngoscop...
This study compared intracuff pressure (ICP) during mechanical ventilation in a variety of currently used endotracheal (ET) and tracheostomy (trach) tube cuffs and related cuff physical characteristics. Tracheostomy tube physical characteristics were also measured. Variation was observed to exist between "just-seal" inspiratory and end-expiratory intracuff pressure during mechanical ventilation...
Dual-cannulae tracheostomy tubes with low-pressure cuffs, such as the Shiley LPC, are widely regarded as inherently safer than single lumen tubes with low-volume cuffs. For the patient who undergoes tracheostomy for failure to wean from mechanical ventilation, however, the insertion of a tube that occupies a large amount of space within the trachea can delay subsequent efforts to liberate him f...